Bunn TNTF-3, TNT-3 manual Brew Solenoid Valve Iced Tea, SERVICE cont, solenoid valve

Models: TNT-3 TNTF-3

1 30
Download 30 pages 2.62 Kb
Page 16
Image 16
BREW SOLENOID VALVE (ICED TEA)

SERVICE (cont.)

If continuity is not present as described, replace the

BREW SOLENOID VALVE (ICED TEA)

solenoid valve.

 

 

 

6.

Check the iced tea solenoid valve for coil action.

 

 

 

Connect the brewer to the power source. With

 

 

 

ICED/OFF/HOT switch in the "ICED" position press

 

 

 

the start switch and listen carefully in the vicinity

 

 

 

of the solenoid valve for a "clicking" sound as the

 

 

 

coil magnet attracts.

 

 

7.

Disconnect the brewer from the power source.

 

 

If the sound is heard as described and water will not

 

 

pass through the solenoid valve, there may be a block-

 

 

age in the water line before the solenoid valve, or the

 

 

solenoid valve may require inspection for wear, and

 

 

removal of waterborne particles.

 

 

If the sound is not heard as described, replace the

 

 

solenoid valve.

 

 

FIG. 4 ICED TEA BREW SOLENOID VALVE P1391.60

Removal and Replacement:

 

1.

Remove all wires from solenoid valves.

Location:

2.

Turn off the water supply to the brewer.

 

Viewing the brewer from the rear, the iced tea brew

3.

Disconnect the water lines to and from the sole-

solenoid valve is mounted in the center of the mount-

 

noid valves.

 

ing bracket.

4.

Remove the two #8-32 keps nuts holding the

 

 

 

mounting bracket to the brewer base.

Test Procedures:

5.

Lift out the bracket.

 

1. Disconnect the brewer from the power source.

6.

Remove the two #10-32 slotted-head screws hold-

2. Disconnect the white/violet and white/blue wires

 

ing the iced tea brew solenoid valve to the mount-

 

from the iced tea brew solenoid valve. With the

 

ing bracket.

 

 

ICED/OFF/HOT switch in the "ICED" position press

7.

Securely install the new iced tea brew solenoid

 

the start switch.

 

valve to the mounting bracket.

3.

With a voltmeter, check the voltage across the

8.

Attach the mounting bracket to the brewer base.

 

white/violet and white/blue wires. Connect the

9.

Securely fasten the water lines to and from the

 

brewer to the power source. The indication must

 

solenoid valves.

 

 

be 120 volts ac for two wire 120 volt models and

10.

Refer to Fig. 5 when reconnecting the wires.

 

three wire 120/208 volt models.

WHI/GRN to Hot Tea

WHI/RED to Hot Tea Timer TL 1

4.

Disconnect the brewer from the power source.

Timer TL 4

WHI/VIO to Dilution Solenoid

 

 

 

 

 

 

WHI/VIO to Iced Tea Brew Timer TL 1

If voltage is present as described, proceed to #5

 

WHI/BLU to Iced Tea Timer TL 4

 

WHI/VIO to Iced Tea

If voltage is not present as described, refer to Wiring

 

 

Brew Timer TL 1

 

Diagram and check brewer wiring harness.

 

 

 

 

5. Check for continuity across the iced tea brew so-

HOT TEA BREW

 

 

 

SOLENOID

 

 

 

lenoid valve coil terminals.

 

 

 

ICED TEA BREW

 

 

 

 

 

WHI/BLU to Iced

 

SOLENOID

 

If continuity is present as described, reconnect the

 

DILUTION

Tea Timer TL 4

 

 

 

white/violet and white/blue wires from the iced tea

 

SOLENOID

 

 

brew timer.

FIG.5 SOLENOID VALVE TERMINALS

P1364

 

Page 16

 

 

28201

081598

 

 

 

 

Page 16
Image 16
Bunn TNTF-3, TNT-3 manual Brew Solenoid Valve Iced Tea, SERVICE cont, solenoid valve