TROUBLESHOOTING (cont.) |
|
PROBLEM | PROBABLE CAUSE |
Brew cycle(s) will not start (cont.) | 6. Brew Timer |
| A) Iced Tea |
REMEDY
Refer to Service - Brew Timer (Iced Tea) for testing procedures. See page 20 or 21
B)Hot Tea
7.Brew Solenoid Valve
A)Iced Tea
B)Hot Tea
Refer to Service - Brew Timer (Hot Tea) for testing procedures. See page 17 or 18
Refer to Service - Brew Solenoid Valve (Iced Tea) for testing proce- dures. See page 16
Refer to Service- Brew Solenoid Valve (Hot Tea) for testing proce- dures. See page 15
8. Internal Flow control (.222 GPM) (Hot Tea Only)
Brew water is not hot | 1. Limit Thermostat |
| |
| CAUTION - Do not eliminate or by- | ||
| pass limit thermostat. Use only | ||
| BOM | replacement | part |
| #29329.1000 |
|
(A)Direction of flow arrow must be pointing towards brewer.
(B)Remove the flow control and check for obstructions. Clear or re- place.
Refer to Service - Limit Thermostat for testing procedures. See page 25
2. Thermal Fuse
CAUTION - Do not eleminate or by- pass thermal fuse.
3. Control Thermostat
Refer to Service - Thermal fuse for testing procedures. See page 29
Refer to Service - Control Thermo- stat for testing procedures. See page 23
Dilution (Iced Tea) cycle will not start
4. Tank Heater
1. ICED/OFF/HOT Switch
Refer to Service - Tank Heater for testing procedures. See page 28
Refer to Service - ICED/OFF/HOT Switch for testing procedures. See page 26