Bunn TNT-3, TNTF-3 manual Problem, Weak beverage, Remedy

Models: TNT-3 TNTF-3

1 30
Download 30 pages 2.62 Kb
Page 13
Image 13

TROUBLESHOOTING (cont.)

 

 

PROBLEM

PROBABLE CAUSE

Weak beverage

1. Filter Type

 

2.

Tea

 

3.

Sprayhead

 

4.

Funnel Loading

 

5.

Water Temperature

Dry tea leaves remain in the

1. Funnel Loading

funnel

 

 

Brewer is making unusal noises

1.

Solenoid(s)

 

2.

Plumbing Lines

 

3.

Water Supply

4. Tank Heater

Page 13

REMEDY

BUNN® paper filters must be used for proper extraction.

A sufficient quantity of fresh, loose tea leaves should be used for proper extraction.

Asix-hole stainless steel spray- head must be used for proper ex- traction.

The BUNN® paper filter must be cen- tered in the funnel and the bed of tea leaves leveled by gentle shaking.

Place an empty funnel on an empty dispenser beneath the sprayhead. Ini- tiate a brew cycle and check the wa- ter temperature immediately below the sprayhead with a thermometer. The reading should not be less than 200°F (93°C). Adjust the control ther- mostat to increase the water tempera- ture. Replace if necessary.

The BUNN® paper filter must be cen- tered in the funnel and the bed of grounds leveled by gently shaking.

The nut on the solenoid(s) must be tight or it will vibrate during opera- tion.

Plumbing lines should not be rest- ing on the counter top.

(A)The brewer must be connected to a cold water line.

(B)Water pressure to the brewer must not exceed 90 psi (620 kPa). Install a regulator if necessary to lower the working pressure to ap- proximately 50 psi (345 kPa).

Remove and clean lime off the tank heater. See page 28

28201 081500

Page 13
Image 13
Bunn TNT-3, TNTF-3 manual Problem, Weak beverage, Remedy