TABLE 3: TANKLESS HEATER DATA: Rear

Mounted Heater on Steam and Water

Boilers

 

 

Heater Rating

Pressure Drop

Boiler

Heater

thru Heater

(GPM)

(PSI)

Model

No.

 

 

 

 

 

 

 

 

Steam

Water

Steam

Water

 

 

 

 

 

 

V713

V1-2

---

3.25

---

5.6

 

 

 

 

 

 

V73

V1-2

2.75

3

3.9

4.7

 

 

 

 

 

 

V714

V1-1

---

3.5

---

4.4

 

 

 

 

 

V1-2

---

4

---

8

 

 

 

 

 

 

 

V74

V1-2

3

3.25

4.7

5.6

 

 

 

 

 

 

V75

V1-2

3.25

3.5

5.6

6.4

 

 

 

 

 

 

V76

V1-2

3.75

3.75

7.2

7.2

 

 

 

 

 

 

V77

V1-2

3.75

4

7.2

8

 

 

 

 

 

 

V78

V1-2

4

4.5

8

9.8

 

 

 

 

 

 

V79

V1-2

4

4.5

8

9.8

 

 

 

 

 

 

TABLE 3A: TANKLESS HEATER DATA: Front Mounted Heater on Water Boilers

Boiler

Heater

Heater Rating

Pressure Drop

Model

No.

(GPM)

Thru Heater (PSI)

 

 

 

 

V73

222

3

22

 

 

 

 

V74

222

3.5

22

 

 

 

 

V75

222

4

30.5

 

 

 

 

V76

222

4.5

33

 

 

 

 

V77

222

4.6

33

 

 

 

A54

5.5

36

 

 

 

 

 

V78

222

4.75

40

 

 

 

A54

6

39.5

 

 

 

 

 

V79

222

4.75

40

 

 

 

A54

6

39.5

 

 

 

 

 

cold water with the hot. This prevents excessive and possibly scalding hot water at the fixtures. In addition, savings of hot water will be achieved since the user will not waste as much hot water while seeking water temperature to his liking. Higher temperature hot water required by dishwashers and automatic washers is possible by piping the hot water from the heater prior to entering the mixing valve. The mixing valve should be “trapped” by installing it below the cold water inlet to heater to prevent lime formation in the valve.

WARNING

Install an automatic mixing valve at the tankless heater outlet to avoid risk of burns or scalding due to excessively hot water at the fixtures. Adjust and maintain the mixing valve in accordance with the manufacturer's instructions.

3.FLUSHING OF HEATER — All water contains some sediment which settles on the inside of the coil. Consequently, the heater should be periodically backwashed. This is accomplished by installing hose bibs as illustrated and allowing water at city pressure to run into hose bib A, through the heater, and out hose bib B until the discharge is clear. The tees in which the hose bibs are located should be the same size as heater connections to minimize pressure drop.

4.HARD WATER — A water analysis is necessary to determine the hardness of your potable water. This is applicable to some city water and particularly to well water. An appropriate water softener should be installed based on the analysis and dealer’s recommendation. This is not only beneficial to the tankless heater but to piping and fixtures plus the many other benefits derived from soft water.

NOTE: STEAM BOILERS

a.During summertime operation, the normal water line should be raised 1”, from 22-5/8” to

23-5/8” (see Figure 1C) for improved tankless heater performance.

G.INSTALL SMOKEPIPE — The V7 should be vented into a fireclay tile-lined masonry chimney or chimney constructed from type L vent or a factory built chimney that complies with the type HT requirements of UL103. The chimney and vent pipe shall have a sufficient draft at all times, to assure safe proper operation of the boiler. See Figure 13 for recommended installation.

1.Install a draft regulator (supplied with boiler) following the instructions furnished with the regulator. See Figure 14 for alternate draft regulator locations.

2.Consider the chimney overall. Chimneys that have

ahigh heat loss may become less suitable as the heat loss of the home goes down and the efficiency of the boiler installed goes up. Most homes have a chimney appropriate for the fuel and the era in which the home was built. That may have been a coal fired or an inefficient oil fired boiler built into

ahome without insulation or storm windows. With increasing fuel prices that home probably has been insulated and fitted with storm windows so that the heat loss of the home has been reduced. This

15

Page 15
Image 15
Burnham V7 SERIES manual Tankless Heater Data Rear, Tankless Heater Data Front Mounted Heater on Water Boilers

V7 SERIES specifications

The Burnham V7 Series is a standout choice in the realm of residential and light commercial boilers, known for its high efficiency and dependable performance. Engineered for those seeking a reliable heating solution, the V7 Series integrates advanced technologies that prioritize both effectiveness and energy conservation.

At the heart of the Burnham V7 Series is its innovative design that utilizes a cast iron heat exchanger. This robust component ensures excellent durability and longevity while providing efficient heat transfer. The V7's heat exchanger is designed to maximize heating output while minimizing fuel consumption, making it an environmentally friendly option that can help reduce utility costs.

One of the key features of the V7 Series is its ability to operate on multiple fuel sources, including natural gas and propane. This versatility allows homeowners and businesses to choose the most suitable and cost-effective fuel option for their specific needs. The V7 also supports a variety of installation configurations, which makes it adaptable to different spaces and configurations.

The series is equipped with advanced control technologies, including a state-of-the-art electronic ignition system. This system enhances reliability by ensuring a quick and safe start-up while reducing energy waste. Additionally, the integrated boiler control allows users to monitor and adjust their heating settings easily, providing enhanced comfort and efficiency at the touch of a button.

Safety is a top priority in the Burnham V7 Series, which features built-in safety controls to minimize risks. These include thermal overload protection, a pressure relief valve, and a low water cutoff feature, all of which work together to safeguard the boiler and its surroundings.

Moreover, the Burnham V7 Series is designed with a user-friendly interface that makes maintenance straightforward. Routine tasks can be conducted with ease, helping to extend the life of the unit.

In conclusion, the Burnham V7 Series is crafted for those who prioritize efficiency, adaptability, and safety in their heating solutions. With its myriad features and commitment to energy conservation, it stands as a leading choice for heating needs in various settings. The combination of innovative technology, reliable performance, and user-friendly design makes the V7 Series an excellent investment in comfort and efficiency.