Fig. 24: "L1" and "V1" Head Electrode Positioning and Gun Setting (Beckett AFG)
5.TURN “OFF” BURNER and remove pressure gauge. Install gauge port plug and tighten. Start burner again.
6.CAD CELL LOCATION AND SERVICE
The burner is supplied with a cadmium sulfide flame detector mounted at the factory, mounted on the bottom of the ignitor. See Figure 25. To service cad cell or to replace the plug in portion, swing open the ignitor. After service is complete, be sure to fasten down the ignitor.
7. FLAME FAILURE |
| |
The V7 boiler controls operate the burner |
| |
automatically. If for unknown reasons the burner |
| |
ceases to fire and the reset button on the primary |
| |
control has tripped, the burner has experienced |
| |
ignition failure. Before pressing the reset button | Figure 25: Cad Cell Location | |
call your serviceman immediately. | ||
|
23