OPERATION
Problem | Possible Cause | Remedy |
|
|
|
Hydraulic Pump not shutting | Using Open Center Valve | Replace Valve or Conversion Plug |
off on Closed Center System |
| and Main Relief |
| Open Center Conversion Plug | Replace with Closed Center Plug |
| Pumping over Relief Valve | Replace with No Relief Plug |
|
|
|
Oil leaking at hose | Connection not tight | Tighten connection |
connection | Did not use sealant | Apply a good sealant to connection |
| Connection cracked from | Replace cracked connection |
|
| |
| Mismatched Connection threads | Use correct connectors |
| or types. |
|
300 Series 09/10 | Operation Section |
© 2010 Alamo Group Inc.