4.2TROUBLESHOOTING CHECKLIST

Troubleshooting Checklist

4.2TROUBLESHOOTING CHECKLIST

If the 6E233-49 SmartSwitch is not working properly, refer to Table 4-2for a checklist of possible problems, causes, and recommended actions to resolve the problem.

 

 

Table 4-2 Fault Identification

 

 

Symptom

Possible Causes

 

 

 

All LEDs are off.

1.

Installation error - remove 6E233-49 SmartSwitch and perform

 

 

installation in accordance with installation instructions. Check

 

 

connectors for dust or dirt and clean as necessary.

 

2.

Power system fault - refer to Table 4-3.

 

 

 

Module stays in BOOT

1.

Device does not have an operable firmware image, and is

state.

 

sending out BootP requests in an effort to locate a BootP server

 

 

on the network. Press the RESET button on the front panel to

 

 

attempt to use the firmware image in FLASH memory.

 

2.

If the problem continues after pressing the RESET button, refer

 

 

to Section B.1 for instructions on forcing a BootP image

 

 

download.

 

3.

Contact Cabletron Systems if the problem continues.

 

 

 

Troubleshooting 4-5

Page 43
Image 43
Cabletron Systems 6000 manual Troubleshooting Checklist