Dear customer, we thank you and compli- ment you for having purchased one of our products.

The warnings and suggestions that follow concern the phases for proper installation, use and maintenance for your safety and for the best use of the appliance.

1.DATA PLATE

The data plate is positioned on the right side panel.

The technical characteristics are identified in the enclosed page “technical data”.

2.CERTIFICATIONS

CSA C-US BRAND

SERIE XA

Certificate of Compliance

N.202281-1008284

Applicable Requirements:

CAN/CSA-C22.2 No. 100-1995 - Motors and

Generators.

CSA Std C22.2 No. 109-M1981 – Commercial

Cooking Appliances.

UL Std No. 197 - Commercial Electric Cooking

Appliances.

UL Std No. 1004 - Electric Motors

The “C” and “US” indicator adjacent to the CSA Mark signifies that the product has been evaluated to the applicable ANSI/UL and CSA Standards, for use in the U.S. and Canada. This includes products eligible to bear the NRTL indicator. NRTL, i.e. Nationally Recognized Testing Laboratory, is a designa- tion granted by the U.S. Occupational Safety and Health Administration (OSHA) to labora- tories which have been recognized to per- form certification to U.S. Standards.

NSF BRAND

SERIE XA

Certificate N. 79610/79610B N. 79610/79611/B

NSF International recognizes UNOX SPA

products as complying with ANSI/NSF 04. Standard 004 - Commercial Cooking, Rethermalization and Powered Hot Food.

3.INSTALLATION – Preliminary Operations

All the electrical connections and installations must be done by qualified personnel in com- pliance with all local codes.

3.1FEET ASSEMBLY (If applicable)

The Cadco-Unox models OV-250 and OV- 350 are shipped with feet installed. Some other model ovens are shipped without the feet being installed, and must be assembled. If your convection oven has feet, do not install or use the oven without them. The feet are shipped in the cooking cavity and must be assembled.

Screw the support feet into the bottom of the oven as shown in the illustration. After assembling the feet, the oven’s height may be adjusted by screwing or unscrewing the feet to level the unit.

The models OV-500 and OV-600 require washers when the feet are assembled.

NOT USE YOUR OVEN
INSTALLING THE FEET.