Configuring the 6300 Control System

Configuring the 6300 Control System

The 6300 control system requires higher power than other 240V systems. Dip switch #10 is factory set in the ON position. This causes the heater to shut off when any pump is running in high speed. To allow the heater to continue operating, dip switch #10 must be set to the OFF position.

To ensure your spa functions properly, ensure the following steps are performed before starting your spa:

When installing the electrical system, use a 60 amp GFCI. Follow the GFCI wiring diagram on the next page.

Have your dealer or installer set dip switch #10 to the OFF position on the circuit board as shown at right.

Electrical Installation for 11 kW Heater

This applies to Ultimate Fitness spas with the 11 kW heater only.

Two electrical services are required to heat the swim side of the Fitness Spa.

2009 Portable Spa

5 Preparingfor

Your New Portable Spa

LTR20091000, Rev. A

www.calspas.com