TROUBLESHOOTING

 

 

Possible Cause

 

Solution

Problem

 

 

 

 

 

Burners will not light

 

Burners not assembled cor-

using the igniter

 

rectly

 

 

 

 

 

 

 

 

Not pausing long enough

 

 

before clicking the control

 

 

panel knob

 

 

 

 

 

 

 

 

No spark

 

 

 

See Step 7 - Install Burners of the Assembly Instructions

When lighting the 1st (Leftmost) Burner, push-in and turn con- trol panel knob counter-clockwise until you feel resistance with turning. Pause 4 seconds with knob still pushed in, then contin- ue turning knob counter-clockwise until a click is heard

Gas collector tab is bent (making too large or small of a gap between electrode and tab). By hand, bend gas collector tab back within a maximum of 3/16” gap to electrode. (See page 12 for illustration).

LP gas cylinder is empty

Coupling nut is not fully con- nected to regulator

Excess flow valve tripped in regulator

Obstructions in burners

Electrodes and burners are wet

Wire is loose or disconnected

Wire is shorting (sparking between igniter and electrode)

Take LP gas cylinder to licensed LP gas supplier to be refilled.

Tighten coupling nut by hand about one-half to three quarters additional turn. Do not use tools.

Turn control knobs to “off” position and turn LP gas cylinder valve clockwise until it stops. Wait five minutes. Open cylinder and relight LP gas grill.

Clean burners (See Burner Maintenance in Care and Maintenance section of this manual)

Dry electrode with clean cloth.

Reconnect the wire.

Replace igniter wire/electrode assembly (Call the Customer Service Department at 1-800-251-7558).

Burners will not light

 

Burners not assembled cor-

 

See Step 7 - Install Burners page of the Assembly Instructions

using a match

 

rectly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP gas cylinder is empty

Take LP gas cylinder to licensed LP gas supplier to be refilled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excess flow valve tripped in

Turn control knobs to “off” position and turn LP gas cylinder

 

 

regulator

 

valve clockwise until it stops. Wait five minutes. Open cylinder

 

 

 

 

and relight LP gas grill.

 

 

 

 

 

 

 

 

 

 

 

 

Coupling nut is not fully con-

Tighten coupling nut by hand about one-half to three quarters

 

 

nected to regulator

 

additional turn. Do not use tools.

 

 

 

 

 

 

 

 

 

 

 

 

Obstructions in burners

 

Clean burners (See Burner Maintenance in Care and

 

 

 

 

Maintenance section of this manual)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low flame or low heat

 

 

 

 

Gas in LP cylinder is low

Check LP gas cylinder. Refill if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

Excess flow valve tripped in

Turn control knobs to “off” position and turn LP gas cylinder

 

 

regulator

 

valve clockwise until it stops. Wait five minutes. Relight LP gas

 

 

 

 

 

 

 

grill. If flame continues to be low, turn off gas at cylinder and

 

 

 

 

grill. Disconnect the regulator from the LP gas cylinder.

 

 

 

 

Reconnect the regulator to the LP gas cylinder. Perform a leak

 

 

 

 

test. Relight grill. This will reset the excess flow valve.

 

 

 

 

 

 

 

 

 

 