| Operating Instructions |
|
|
|
| FP2000, FP2012 |
| |
|
|
|
|
|
|
| ||
| Troubleshooting Chart |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Symptom |
| Possible Cause(s) | Corrective Action |
|
|
| |
| Compressor will not run | 1. | Loss of power or overheating | 1. Check for proper use of extension cord (see EXTENSION |
| |||
|
|
|
| CORDS, page 3) |
|
|
| |
|
| 2. | No electrical power | 2. Plugged in? Check fuse/breaker |
| |||
|
| 3. | Blown fuse | 3. Replace blown fuse |
| |||
|
| 4. Breaker open | 4. Reset. Determine why problem happened |
| ||||
|
| 5. | Thermal overload open | 5. Motor will restart when cool |
| |||
|
| 6. | Pressure switch bad | 6. Replace |
|
|
| |
|
|
|
|
|
| |||
| Motor hums but cannot | 1. Low voltage | 1. Check with voltmeter |
| ||||
| run or runs slowly | 2. | Wrong gauge wire or length of | 2. Check gauge chart under Operation for proper gauge |
| |||
|
|
| extension cord | wire and cord length |
| |||
|
| 3. Shorted or open motor winding | 3. Replace motor |
|
|
| ||
|
| 4. | Defective check valve or unloader | 4. Replace or repair |
|
|
| |
|
| 5. | Unit is cold, oil too thick | 5. Use |
| |||
|
| 6. | Low oil level | 6. Add oil to full line on dipstick |
| |||
|
| 7. | Defective capacitor | 7. Replace or repair |
|
|
| |
|
|
|
|
|
| |||
| Fuses blow/circuit | 1. | Incorrect size fuse, circuit overloaded | 1. Check for proper fuse, use |
| |||
| breaker trips repeatedly |
|
| other electrical appliances from circuit or operate |
| |||
|
|
|
| compressor on dedicated branch circuit |
| |||
|
| 2. | Wrong gauge wire or length of | 2. Check gauge chart, under Operation |
| |||
|
|
| extension cord |
|
|
|
|
|
|
| 3. | Defective check valve or unloader | 3. Replace or repair |
|
|
| |
|
| 4. | Low oil level | 4. Add oil to full line on dipstick |
| |||
|
|
|
|
|
|
| ||
| Thermal overload | 1. | Low voltage | 1. Check with voltmeter |
| |||
| protector cuts out | 2. | Clogged air filter | 2. Clean filter (see Maintenance section) |
| |||
| repeatedly | 3. | Lack of proper ventilation/room | 3. Move compressor to well ventilated area |
| |||
|
|
| temperature too high |
|
|
|
|
|
|
| 4. | Wrong gauge wire or length of | 4. Check gauge chart, under Operation |
| |||
|
|
| extension cord |
|
|
|
|
|
|
| 5. | Low oil level | 5. Add oil to full line on dipstick |
| |||
|
|
|
|
|
|
| ||
| Tank pressure drops | 1. | Loose connections (fittings, tubing, etc.) | 1. Check all connections with soap and water solution and |
| |||
| when compressor shuts | 2. | Loose drain lock | tighten |
|
|
| |
| off | 3. | Check valve leaking | 2. Tighten |
|
|
| |
|
|
|
| 3. Disassemble check valve assembly, clean or replace |
| |||
|
|
|
|
|
| Do not disassemble check valve |
| |
|
|
|
| ! DANGER |
|
| ||
|
|
|
|
| with air in tank; bleed tank |
| ||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
| Excessive moisture in | 1. | Excessive water in air receiver | 1. Drain receiver |
|
|
| |
| discharge air | 2. | High humidity | 2. Move to area of less humidity; use air line filter |
| |||
|
|
|
|
|
|
|
| |
| Compressor runs | 1. | Defective pressure switch | 1. Replace switch |
|
|
| |
| continuously | 2. | Excessive air usage | 2. Decrease air usage; compressor not large enough for air |
| |||
|
|
|
| requirement |
|
|
| |
|
| 3. | Air leak | 3. Repair or replace leaking component |
| |||
|
|
|
|
|
| |||
| Compressor vibrates | Loose mounting bolts | Tighten pump mounting bolts so rubber washer is |
| ||||
|
|
|
| slightly compressed |
|
|
| |
|
|
|
|
| ||||
| Compressor “walks” on | Foot mounting bolts not securely | Tighten foot mounting bolts underneath tank assembly |
| ||||
| hard surfaces | tightened |
|
|
|
|
| |
|
|
|
|
|
| |||
| Air output lower than | 1. | Broken valves | 1. Have authorized service representative repair unit |
| |||
| normal | 2. | Intake filter dirty | 2. Clean or replace intake filter |
| |||
|
| 3. | Connections leaking | 3. Tighten connections |
|