Installation (Continued)

! DANGER Do not use a grounding adapter with this product!

2.If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.

 

Never connect

! WARNING

green (or green and

yellow) wire to a live terminal.

3. Check with a qualified electrician or

serviceman if grounding instructions

are not completely understood, or if in

doubt as to whether product is

properly grounded. Do not modify

plug provided; if it will not fit outlet,

Tank gauge

Safety valve

On/off switch

Outlet gauge

Regulator

Figure 2 - Unit Identification

29

38

1

35 36

43

34

33

9

31

16

25

27

27

10

7

2

11

 

 

 

20

21 19

 

 

20

 

18

21

50

48

19

49

51

 

32

 

 

 

3

 

 

 

 

 

 

 

40

 

 

 

39

 

 

 

52

 

 

 

53

 

 

46

 

 

 

45

 

 

 

24

 

 

 

 

44

5

28

14

12

30

54

qualified electrician.

! CAUTION

Overheating, short

circuiting and fire

damage will result from inadequate wiring, etc.

WALL MOUNTING

This compressor can be mounted to the wall for convenient storage. It can also be operated while in the hanging position.

Before mounting, select a location at a wall stud or on a concrete surface. Make sure that the mounting area measures at least 24” x 30”.

Hang compressor on

!WARNING a properly installed hanger sturdy enough to support compressor’s weight (approximately 25 pounds). Do not hang on peg board, wallboard, or any structure not suited to hold compressor’s weight.

Mounting hanger bracket

For mounting to a wood stud, the bracket has three holes in the center. These holes are located in between the two mounting hooks that attach to the back of the compressor. Use a stud finder to locate the center of the stud.

Use the screws provided to attach the bracket to the wall. Make sure to mount to the wood stud, not just to drywall.

For mounting to a concrete surface, pre-drill holes in the concrete and insert the anchors that are provided. Align the holes in the bracket with the wall anchors and use the three screws provided to attach the bracket to the wall.

Avoid mounting compressor to drywall or gypsum board unless screws are lagged into wood studs.

Mounting air compressor to bracket

There are three mounting hooks on the wall hanging bracket. On the back of the compressor shroud, there is an opening that serves as a handle. The two hooks on the top of the bracket fit in the handle opening on the compressor shroud. The remaining hook on the bottom of the bracket fits into the lower part of the compressor shroud, below the handle opening.

HOSE STORAGE

1.Attach one of the threaded ends of recoil hose to air outlet on front of

Extension cords for 120V/2.5 Amp Unit

compressor.

2.Route recoil hose to side of tank where hose strap is located.

3.Loosen lower end of hose strap.

4.Slide as much of recoil as possible onto hose strap.

5.Reattach hose strap to compressor.

Operation

Definition of Terms

Regulator - The regulator controls the amount of air pressure released at the hose outlet.

ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.

Handle - Designed to move the compressor.

Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.

Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture

13

FP2051, FP2052

Length of Cord (ft)

25

50

100

150

200

250

300

400

500

Gauge of Cord

18

18

16

14

14

12

12

10

10

www.chpower.com

26 Sp

3

Page 3
Image 3
Campbell Hausfeld FP2051, FP2052 Operation, Wall Mounting, Hose Storage, Extension cords for 120V/2.5 Amp Unit