Installation (Continued)
! DANGER Do not use a grounding adapter with this product!
2.If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire.
| Never connect | |
! WARNING | ||
green (or green and |
yellow) wire to a live terminal.
3. Check with a qualified electrician or |
serviceman if grounding instructions |
are not completely understood, or if in |
doubt as to whether product is |
properly grounded. Do not modify |
plug provided; if it will not fit outlet, |
Tank gauge | Safety valve |
On/off switch
Outlet gauge
Regulator
Figure 2 - Unit Identification
29
38 |
1
35 36
43
34
33
9
31
16
25
27
27
10
7
2
11 |
|
|
| |
20 | 21 19 |
|
| |
20 |
| 18 | ||
21 | 50 | |||
48 | ||||
19 | 49 | 51 |
| |
32 |
|
| ||
| 3 |
| ||
|
|
| ||
|
|
| 40 | |
|
|
| 39 | |
|
|
| 52 | |
|
|
| 53 | |
|
| 46 |
| |
|
| 45 |
| |
|
| 24 |
| |
|
|
| 44 |
5
28
14
12
30
54
qualified electrician. |
! CAUTION | Overheating, short |
circuiting and fire |
damage will result from inadequate wiring, etc.
WALL MOUNTING
This compressor can be mounted to the wall for convenient storage. It can also be operated while in the hanging position.
Before mounting, select a location at a wall stud or on a concrete surface. Make sure that the mounting area measures at least 24” x 30”.
Hang compressor on
!WARNING a properly installed hanger sturdy enough to support compressor’s weight (approximately 25 pounds). Do not hang on peg board, wallboard, or any structure not suited to hold compressor’s weight.
Mounting hanger bracket
For mounting to a wood stud, the bracket has three holes in the center. These holes are located in between the two mounting hooks that attach to the back of the compressor. Use a stud finder to locate the center of the stud.
Use the screws provided to attach the bracket to the wall. Make sure to mount to the wood stud, not just to drywall.
For mounting to a concrete surface,
Avoid mounting compressor to drywall or gypsum board unless screws are lagged into wood studs.
Mounting air compressor to bracket
There are three mounting hooks on the wall hanging bracket. On the back of the compressor shroud, there is an opening that serves as a handle. The two hooks on the top of the bracket fit in the handle opening on the compressor shroud. The remaining hook on the bottom of the bracket fits into the lower part of the compressor shroud, below the handle opening.
HOSE STORAGE
1.Attach one of the threaded ends of recoil hose to air outlet on front of
Extension cords for 120V/2.5 Amp Unit
compressor.
2.Route recoil hose to side of tank where hose strap is located.
3.Loosen lower end of hose strap.
4.Slide as much of recoil as possible onto hose strap.
5.Reattach hose strap to compressor.
Operation
Definition of Terms
Regulator - The regulator controls the amount of air pressure released at the hose outlet.
ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
Handle - Designed to move the compressor.
Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion.
Reduce tank pressure below 10 psi, then drain moisture from tank daily to avoid tank corrosion. Drain moisture
13
FP2051, FP2052
Length of Cord (ft) | 25 | 50 | 100 | 150 | 200 | 250 | 300 | 400 | 500 |
Gauge of Cord | 18 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 |
www.chpower.com
26 Sp | 3 |