Portable Air Compressor

FP2051, FP2052

General Safety Information (Continued)

3.Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.

4.Keep visitors away and NEVER allow children in the work area.

5.Wear safety glasses

and use hearing protection when operating the pump or unit.

6.Do not stand on or use the pump or unit as a handhold.

7.Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.

8.Check all fasteners at frequent intervals for proper tightness.

! WARNING

Motors, electrical equipment and controls

can cause electrical arcs

that will ignite a flammable gas or vapor. Never operate or repair in or near a flammable gas or vapor. Never store flammable liquids or gases in the vicinity of the compressor.

!CAUTION

Compressor parts may be hot even if the unit is stopped.

9.Keep fingers away from a running compressor; fast moving and hot parts will cause injury and/or burns.

10.If the equipment should start to abnormally vibrate, STOP the engine/motor and check immediately for the cause. Vibration is generally a warning of trouble.

11.To reduce fire hazard, keep engine/motor exterior free of oil, solvent, or excessive grease.

Never remove or ! WARNING attempt to adjust

safety valve. Keep safety valve free from paint and other accumulations.

!DANGER

Never attempt to repair or modify a tank! Welding, drilling or any

other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn or damaged tanks.

Drain liquid from

! WARNING tank daily.

13.Tanks rust from moisture build-up, which weakens the tank. Make sure to drain tank daily and inspect periodically for unsafe conditions such as rust formation and corrosion.

14.Fast moving air will stir up dust and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.

SPRAYING PRECAUTIONS

! WARNING

Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit.

15.Do not smoke when spraying paint, insecticides, or other flammable substances.

16.Use a face mask/

respirator when spraying and spray in a well ventilated area to prevent health and fire hazards.

17.Do not direct paint or other sprayed material at the compressor. Locate compressor as far away from the spraying area as possible to minimize overspray accumulation on the compressor.

18.When spraying or cleaning with solvents or toxic chemicals, follow the instructions provided by the chemical manufacturer.

Installation

LOCATION

It is extremely important to use the compressor in a clean, well ventilated area where the surrounding air temperature will not be more than 100°F.

A minimum clearance of 18 inches between the compressor and a wall is required because objects could obstruct air flow.

Do not locate the

! CAUTION compressor air inlet near steam, paint spray, sandblast areas or any other source of contamination. This debris will damage the motor.

GROUNDING INSTRUCTIONS

1.This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Fig. 1. Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Grounding

Pin

TEST RESET

Grounded Outlet

Figure 1 - Grounding Method

!DANGER

Improper use of grounding plug can result in a possible risk of electrical shock!

Lista de Repuestos

 

 

 

 

 

FP2051, FP2052

 

 

 

 

 

 

 

No. de

Número del

 

 

No. de

Número del

 

Ref. Descripción

repuesto

Ctd.

 

Ref. Descripción

repuesto

Ctd.

 

 

 

 

 

 

 

 

 

1

Cabezal/motor

FP205110AV

1

36

Tuerca M3x2,5

2

2

Patas del chasis

4

 

37

Arandela

2

3

Patas de la cubierta del motor

4

 

38

Ventilador

1

4

Cubierta izquierda del compresor

FP205111AV

1

 

39

Alivio de tensión

1

5

Cubierta derecha del compresor

FP205112AV

1

 

40

Tornillo M4x8

2

6

Panel del manómetro

FP205113AV

1

 

41

Tornillo M3x10

2

7

Chasis

FP205114AV

1

 

42

Sujetador del cableado

1

8

Mango

FP205115AV

1

 

43

Valvula de seguridad

V-215105AV

1

9

Distribuidor (incluye regulador)

FP205116AV

1

 

44

Gancho de la correa

1

10

Bandeja de accesorios

FP205117AV

1

 

45

Correa

1

11

Tubo de escape

1

 

46

Tornillo M4x10

1

12

Soporte de montaje para pared

1

 

47

Fusible

FP205130AV

1

13

Tornillo 1/4x19

4

 

48

Tornillo autorroscante

1

14

Tornillo M6x15

4

 

49

Tubo de goma

2

 

 

4

 

50

Tornillo

1

15

Tornillo M6x200

1

 

51

Tuerca

4

16

Presostato

FP205118AV

1

 

52

Placa fija del motor

1

17

Tablero del circuito

1

 

53

Tuerca

1

18

Cordón eléctrico

1

 

54

Tornillo para madera

3

19

Conexión de compresión

2

 

JUEGOS DE REPUESTOS

 

 

20

Tuerca de compresión

2

 

Juego de montaje del motor

FP205131AV

 

21

Manga

2

 

Juego de las patas del chasis

FP205120AV

 

22

Arandela de 6,4 mm (1/4”)

 

 

 

Juego de montaje para pared

FP205121AV

 

 

(No se muestra)

4

 

Juego de tubos

FP205122AV

 

 

 

4

 

Juego de tornillos de la cubierta

FP205123AV

 

23

Interruptor de encendido/apagado FP205129AV

1

 

Juego del tablero de circuitos

FP205124AV

 

24

Válvula de drenaje

D-1403

1

 

Juego del cordón de corriente

FP205125AV

 

25

Accesorios de inflado

1

 

Juego de la válvula de chequeo

FP205126AV

 

26

Adaptador

1

 

Juego del ventilador

FP205127AV

 

27

Boquilla para neumático

1

 

Juego de la correa

FP205128AV

 

28

Tuerca de retención de la cubierta ▼

1

 

Kit de herramienta

FP204008AV

 

29

Tornillo 3x8

5

 

 

Juego para calcomanía (No se muestra)

 

30

Tornillo de fijación para hormigón

3

 

 

Modelo FP2051

FP205132AV

 

31

Valvula de chequeo

1

 

 

Modelo FP2052

FP205221AV

 

32

Resorte

1

 

 

 

 

 

33

Manómetro de salida

FP006300AV

1

 

 

 

 

 

34

Manómetro del tanque

GA016304AV

1

 

 

 

 

 

35

Tornillo M3x10

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.chpower.com

2

27 Sp

Page 2
Image 2
Campbell Hausfeld Installation, Portable Air Compressor FP2051, FP2052, Lista de Repuestos FP2051, FP2052