Symptom

Possible Cause(s)

 

Corrective Action

 

Tank pressure drops

1.

Loose drain valve

3. Replace or repair as necessary.

 

when compressor shuts

2.

Check valve leaking

1.

Tighten.

 

off

3.

Loose connections at fittings, tubing,

2.

Remove check valve. Clean or replace.

 

 

 

etc.

3.

Check all connections with soap and water solution.

 

 

 

 

 

 

If a leak is detected, (1) tighten or (2) remove fitting

 

 

 

 

 

 

and apply pipe tape to threads and reassemble.

 

 

4.

Tank leaks

4.

Check tank for leaks with soap and water solution. If

 

 

 

 

 

 

leak is detected, tank must be replaced with genuine

 

 

 

 

 

 

replacement part.

 

 

 

 

 

 

 

Do not disassemble check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valve with air in tank;

 

 

 

 

 

 

 

 

 

 

 

bleed tank

 

 

 

 

 

 

 

 

 

Compressor runs

1.

Excessive air usage, compressor too

1.

Decrease usage or purchase unit with higher air

 

continuously and air

 

small

 

 

delivery (SCFM).

 

output is lower than

2.

Clogged intake filter

2.

Clean or replace.

 

normal/low discharge

3.

Loose connections at fittings, tubing,

3.

Check all connections with soap and water solution.

 

pressure

 

etc.

 

 

If a leak is detected, (1) tighten or (2) remove fitting

 

 

 

 

 

 

and apply pipe tape to threads and reassemble.

 

 

4.

Tank leaks

4.

Check tank for leaks with soap and water solution. If

 

 

 

 

 

 

leak is detected, tank must be replaced with genuine

 

 

5.

Broken valves

 

 

replacement part.

 

 

6.

Piston ring worn

5.

Replace compressor valves as necessary.

 

 

 

 

6.

Replace piston rings.

 

 

 

 

 

 

 

 

 

Excessive moisture in

1.

Excessive water in tank

1.

Drain tank.

 

discharge air

2.

High humidity

2.

Move to area of less humidity; use air line filter.

 

 

 

 

 

 

NOTE: Water condensation is not caused by

 

 

 

 

 

 

compressor malfunction.

 

 

 

 

 

 

 

Compressor runs

1.

Defective pressure switch

1.

Replace switch.

 

continuously and safety

2.

Defective safety valve

2.

Replace safety valve with genuine replacement part.

 

valve opens as pressure

 

 

 

 

 

 

 

rises

 

 

 

 

 

 

 

 

 

 

 

 

 

Excessive starting and

1.

Excessive condensation in tank

1.

Drain more often.

 

stopping (auto start)

2.

Loose connections at fittings, tubing,

2.

Check all connections with soap and water solution.

 

 

 

etc.

 

 

If a leak is detected, (1) tighten or (2) remove fitting

 

 

 

 

 

 

and apply pipe tape to threads and reassemble.

 

 

3.

Tank leaks

3.

Check tank for leaks with soap and water solution. If

 

 

 

 

 

 

leak is detected, tank must be replaced with genuine

 

 

 

 

 

 

replacement part.

 

 

 

 

 

 

 

Do not disassemble check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

valve with air in tank;

 

 

 

 

 

 

 

 

 

 

 

bleed tank

 

 

 

 

 

 

 

Air leaking from

1.

Check valve stuck in an open position

1.

Repair or replace check valve.

 

unloader valve on

2.

Unloader valve stuck in open position

2.

Repair or replace unloader valve.

 

pressure switch

 

 

 

 

 

Do not disassemble check

 

 

 

 

 

 

 

 

 

 

 

 

 

valve with air in tank;

 

 

 

 

 

 

 

 

 

 

 

bleed tank

 

 

 

 

 

 

 

 