Assembly (Continued) |
|
|
|
|
|
|
| ||
3. Repeat procedure with other side. |
|
|
| Grounding |
|
|
| ||
|
|
| Pin |
|
|
| |||
LUBRICATION |
|
|
|
|
|
|
|
| |
THIS UNIT IS |
|
|
|
|
|
|
|
| |
SHIPPED WITHOUT |
|
|
|
| Grounded Outlet | ||||
OIL! Follow lubrication instructions |
|
|
|
| |||||
|
|
|
|
|
|
| |||
before operating compressor. |
|
|
|
| Figure 5 - Grounding Method |
|
| ||
|
|
|
|
|
|
| |||
Use oil shipped with the compressor. |
|
|
| ELECTRICAL INSTALLATION |
|
| |||
Do not use regular automotive oil |
|
|
|
|
| ||||
|
|
| All wiring and |
| |||||
such as |
|
|
|
| |||||
|
|
| electrical |
|
| ||||
synthetic oil. Additives in regular | Figure 4 - Intake filter installation |
|
| ||||||
connections should be performed by a | |||||||||
motor oil can cause valve deposits and | INTAKE FILTER |
| qualified electrician. Installation must | ||||||
reduce pump life. For maximum pump |
| be in accordance with local codes and | |||||||
Thread the intake air filter into the | national electrical codes. |
|
| ||||||
life, drain and replace oil after the first |
|
| |||||||
threaded opening in the side of the |
|
|
|
| |||||
few hours of run time. |
| WIRING |
|
|
| ||||
The compressor pump takes approxi- | compressor head as illustrated in | 1. Local electrical wiring codes differ from | |||||||
Figure 4. Tighten gently with a wrench. | |||||||||
area to area. Source wiring, plug and | |||||||||
mately 220 ml (7.5 ozs.) of oil. The sight | |||||||||
|
|
| protector must be rated for at least the | ||||||
glass, located on the crankcase portion | Installation | ||||||||
amperage and voltage indicated on | |||||||||
of the pump, is marked with “max” | |||||||||
and “min” levels. Avoid overfilling by | LOCATION |
|
| motor nameplate, and meet all |
| ||||
|
| electrical codes for this minimum. |
| ||||||
adding oil gradually and checking the | It is extremely important to install the |
| |||||||
2. Use a slow blow fuse or a circuit |
| ||||||||
oil level with the sight glass several | compressor in a clean, well ventilated |
| |||||||
breaker. |
|
|
| ||||||
times. Add enough oil to reach the | area where the surrounding air |
|
|
| |||||
3. This product is for use on a nominal | |||||||||
“max” level on the sight glass. Proper | temperature will not be more than | ||||||||
oil level is illustrated in Figure 3. |
| 100°F. |
|
| 120 volt circuit and has a grounding | ||||
|
| A minimum clearance of 18 inches | plug that looks like the plug illustrated | ||||||
|
| in Figure 5. Make sure the product is | |||||||
|
| between the compressor and a wall is | |||||||
| Max. | connected to an outlet having the |
| ||||||
| required because objects could obstruct |
| |||||||
| same configuration as the plug. This | ||||||||
| Min. | ||||||||
| air flow. |
|
| product must be grounded. In the |
| ||||
|
|
|
|
| |||||
|
|
|
| Do not locate the | event of an electrical short circuit, |
| |||
|
|
|
| compressor air inlet | grounding reduces risk of electrical |
| |||
|
| near steam, paint spray, sandblast areas | shock by providing an escape wire for | ||||||
Figure 3 - Proper oil level |
| or any other source of contamination. | |||||||
| electric current. This product is |
| |||||||
| This debris will damage the motor. |
| |||||||
|
| equipped with a cord having a |
| ||||||
|
|
|
|
|
| ||||
Side view of unit |
|
| Top view of unit | grounding wire with an appropriate | |||||
|
| grounding plug. Plug must be plugged | |||||||
|
|
|
|
| |||||
Intake filter |
|
|
| into an outlet that is properly installed | |||||
| Oil fill / | Exhaust |
| Pressure Switch | and grounded in accordance with all | ||||
|
| local codes and ordinances. |
|
| |||||
Handle | breather | Tube |
|
|
| ||||
| (Auto/Off) |
|
| ||||||
|
|
| Overheating, short | ||||||
|
|
|
|
| |||||
|
|
|
|
| circuiting and fire | ||||
|
|
|
|
| damage will result from inadequate |
| |||
| Sight |
|
|
| wiring. |
|
|
| |
| glass |
|
|
|
|
|
|
| |
| Oil |
|
|
|
|
|
|
| |
| drain |
|
|
|
|
|
| ||
| plug |
|
|
|
|
|
|
| |
|
|
| Check | Regulator |
|
|
|
| |
|
|
| Valve | Extension cords for |
| ||||
|
|
| Safety |
| |||||
|
|
|
| 120V/15 Amp Unit |
|
| |||
|
|
|
| Valve |
|
| |||
|
|
|
|
|
|
|
| ||
Drain valve |
|
|
|
| Length of Cord (ft) | 25 | 50 | 100 | |
|
|
|
|
| |||||
Figure 6 - Unit Identification |
|
|
|
| Gauge of Cord | 14 | 12 | 10 | |
|
|
|
|
| |||||
|
|
|
|
| www.chpower.com | ||||
|
|
|
| 3 |
|
|
|
|