Campbell Hausfeld HS5500 Assembly Continued, Lubrication, Electrical Installation, Wiring

Models: HS5500

1 24
Download 24 pages 18.62 Kb
Page 3
Image 3
Assembly (Continued)

Assembly (Continued)

 

 

 

 

 

 

 

3. Repeat procedure with other side.

 

 

 

Grounding

 

 

 

 

 

 

Pin

 

 

 

LUBRICATION

 

 

 

 

 

 

 

 

THIS UNIT IS

 

 

 

 

 

 

 

 

SHIPPED WITHOUT

 

 

 

 

Grounded Outlet

OIL! Follow lubrication instructions

 

 

 

 

 

 

 

 

 

 

 

before operating compressor.

 

 

 

 

Figure 5 - Grounding Method

 

 

 

 

 

 

 

 

 

Use oil shipped with the compressor.

 

 

 

ELECTRICAL INSTALLATION

 

 

Do not use regular automotive oil

 

 

 

 

 

 

 

 

All wiring and

 

such as 10W-30 unless it is 100%

 

 

 

 

 

 

 

electrical

 

 

synthetic oil. Additives in regular

Figure 4 - Intake filter installation

 

 

connections should be performed by a

motor oil can cause valve deposits and

INTAKE FILTER

 

qualified electrician. Installation must

reduce pump life. For maximum pump

 

be in accordance with local codes and

Thread the intake air filter into the

national electrical codes.

 

 

life, drain and replace oil after the first

 

 

threaded opening in the side of the

 

 

 

 

few hours of run time.

 

WIRING

 

 

 

The compressor pump takes approxi-

compressor head as illustrated in

1. Local electrical wiring codes differ from

Figure 4. Tighten gently with a wrench.

area to area. Source wiring, plug and

mately 220 ml (7.5 ozs.) of oil. The sight

 

 

 

protector must be rated for at least the

glass, located on the crankcase portion

Installation

amperage and voltage indicated on

of the pump, is marked with “max”

and “min” levels. Avoid overfilling by

LOCATION

 

 

motor nameplate, and meet all

 

 

 

electrical codes for this minimum.

 

adding oil gradually and checking the

It is extremely important to install the

 

2. Use a slow blow fuse or a circuit

 

oil level with the sight glass several

compressor in a clean, well ventilated

 

breaker.

 

 

 

times. Add enough oil to reach the

area where the surrounding air

 

 

 

3. This product is for use on a nominal

“max” level on the sight glass. Proper

temperature will not be more than

oil level is illustrated in Figure 3.

 

100°F.

 

 

120 volt circuit and has a grounding

 

 

A minimum clearance of 18 inches

plug that looks like the plug illustrated

 

 

in Figure 5. Make sure the product is

 

 

between the compressor and a wall is

 

Max.

connected to an outlet having the

 

 

required because objects could obstruct

 

 

same configuration as the plug. This

 

Min.

 

air flow.

 

 

product must be grounded. In the

 

 

 

 

 

 

 

 

 

 

Do not locate the

event of an electrical short circuit,

 

 

 

 

 

compressor air inlet

grounding reduces risk of electrical

 

 

 

near steam, paint spray, sandblast areas

shock by providing an escape wire for

Figure 3 - Proper oil level

 

or any other source of contamination.

 

electric current. This product is

 

 

This debris will damage the motor.

 

 

 

equipped with a cord having a

 

 

 

 

 

 

 

Side view of unit

 

 

Top view of unit

grounding wire with an appropriate

 

 

grounding plug. Plug must be plugged

 

 

 

 

 

Intake filter

 

 

 

into an outlet that is properly installed

 

Oil fill /

Exhaust

 

Pressure Switch

and grounded in accordance with all

 

 

local codes and ordinances.

 

 

Handle

breather

Tube

 

 

 

 

(Auto/Off)

 

 

 

 

 

Overheating, short

 

 

 

 

 

 

 

 

 

 

circuiting and fire

 

 

 

 

 

damage will result from inadequate

 

 

Sight

 

 

 

wiring.

 

 

 

 

glass

 

 

 

 

 

 

 

 

Oil

 

 

 

 

 

 

 

 

drain

 

 

 

 

 

 

 

plug

 

 

 

 

 

 

 

 

 

 

Check

Regulator

 

 

 

 

 

 

 

Valve

Extension cords for

 

 

 

 

Safety

 

 

 

 

 

120V/15 Amp Unit

 

 

 

 

 

 

Valve

 

 

 

 

 

 

 

 

 

 

Drain valve

 

 

 

 

Length of Cord (ft)

25

50

100

 

 

 

 

 

Figure 6 - Unit Identification

 

 

 

 

Gauge of Cord

14

12

10

 

 

 

 

 

 

 

 

 

 

www.chpower.com

 

 

 

 

3

 

 

 

 