CHN10610

Operating Instructions (Continued)

3.Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails, or 150 psi, whichever is greater.. Use 1/4 in.. air hose for runs up to 50 ft.. Use 3/8 in.. air hoses for 50 ft.. run or longer.. For better performance, install a 3/8 in.. quick plug (1/4 in.. NPT threads) with an inside diameter of

..315 in.. (8mm) on the tool and a 3/8 in.. quick coupler on the air hose..

150 psi or greater

3/8 inch I..D..

4.Use a pressure regulator on the compressor, with an operating pressure of 0 psi - 125 psi.. A pressure regulator is required to control the operating pressure of the tool between 60 psi and 100 psi..

Operational Mode

Always know the operational mode of

the tool before using. Failure to know the operational mode could result in death or serious personal injury.

Trigger Only Mode (with Trigger LOCK)

The tool is a single-actuator device.. This mode requires that, with the trigger lock not positioned in the safe mode, only a pull of the trigger will fire a fastener..

After verifying there are no fasteners in the tool, safety check the operation of the activated trigger lock to prevent the tool from firing a fastener before storage.. Always disconnect from

compressed air when not in use..

LOADING/UNLOADING THE TOOL

1.Always disconnect the tool from the air supply before loading fasteners..

2.

Turn stapler upside

 

 

down and pull the

 

 

latch.. Pull back on the

 

 

magazine cover..

 

3. Insert a stick of

 

 

Arrow® T50® staples

 

 

or equivalent (see

 

 

Fastener Section) into the magazine

 

with the crown side down.. Make

 

sure the staples are not dirty or

 

damaged..

 

4.

Push the magazine

 

 

cover forward until

 

 

the latch catches..

 

5.

Always unload all

 

 

fasteners before

 

 

removing tool from

 

 

service.. Unloading

 

 

is the reverse of

 

 

loading, except always disconnect

 

the air hose before unloading..

Adjusting The Direction Of The

Exhaust

 

The tool is

 

equipped with

 

an adjustable

Rotate

direction exhaust

 

deflector.. This is intended to allow the user to change the direction of the exhaust.. Simply twist the deflector to any direction desired..

Clearing A Jam From The Tool

1. Disconnect the air supply from the tool..

2.Remove all fasteners from the magazine (see "Loading/ Unloading The Tool")..

3.With the magazine open, remove the jammed fastener, using pliers, a screwdriver or a pick if required..

4.Close magazine..

User-Maintenance

Instructions

Technical Service

Please call our Tool Hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this tool or for additional copies of this manual..

Fastener And Replacement Parts

Use only Arrow® T50® or equivalent staples.

Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasteners, specify by part number.

Tool Repair

Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently..

Assembly Procedure For Seals

When repairing a tool, the internal parts must be cleaned and lubricated.. Parker O-lube or equivalent must be used on all o-rings.. Each o-ring must be coated with O-lube before assembling.. A small amount of oil must be used on all moving surfaces and pivots.. After reassembling, a few drops of 30W non-detergent oil or equivalent, must be added through the air line before testing..

Storage

The stapler should be stored in a cool dry place..

Fasteners

Fasteners used in this stapler include:

Arrow® T50® staples or any equivalent fastener with the approximate dimensions illustrated below..

1/4 inch - 9/16 inch

6mm - 14mm 1..3mm

10..7mm

9..3mm

0..7mm

www.chpower.com

5