CHN10610
Operating Instructions (Continued)
3.Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source if a regulator fails, or 150 psi, whichever is greater.. Use 1/4 in.. air hose for runs up to 50 ft.. Use 3/8 in.. air hoses for 50 ft.. run or longer.. For better performance, install a 3/8 in.. quick plug (1/4 in.. NPT threads) with an inside diameter of
..315 in.. (8mm) on the tool and a 3/8 in.. quick coupler on the air hose..
150 psi or greater
3/8 inch I..D..
4.Use a pressure regulator on the compressor, with an operating pressure of 0 psi - 125 psi.. A pressure regulator is required to control the operating pressure of the tool between 60 psi and 100 psi..
Operational Mode
Always know the operational mode of
the tool before using. Failure to know the operational mode could result in death or serious personal injury.
Trigger Only Mode (with Trigger LOCK)
The tool is a
After verifying there are no fasteners in the tool, safety check the operation of the activated trigger lock to prevent the tool from firing a fastener before storage.. Always disconnect from
compressed air when not in use..
LOADING/UNLOADING THE TOOL
1.Always disconnect the tool from the air supply before loading fasteners..
2. | Turn stapler upside |
|
| down and pull the |
|
| latch.. Pull back on the |
|
| magazine cover.. |
|
3. Insert a stick of |
| |
| Arrow® T50® staples |
|
| or equivalent (see |
|
| Fastener Section) into the magazine | |
| with the crown side down.. Make | |
| sure the staples are not dirty or | |
| damaged.. |
|
4. | Push the magazine |
|
| cover forward until |
|
| the latch catches.. |
|
5. | Always unload all |
|
| fasteners before |
|
| removing tool from |
|
| service.. Unloading |
|
| is the reverse of |
|
| loading, except always disconnect | |
| the air hose before unloading.. | |
Adjusting The Direction Of The | ||
Exhaust |
| |
The tool is |
| |
equipped with |
| |
an adjustable | Rotate | |
direction exhaust |
|
deflector.. This is intended to allow the user to change the direction of the exhaust.. Simply twist the deflector to any direction desired..
Clearing A Jam From The Tool
1. Disconnect the air supply from the tool..
2.Remove all fasteners from the magazine (see "Loading/ Unloading The Tool")..
3.With the magazine open, remove the jammed fastener, using pliers, a screwdriver or a pick if required..
4.Close magazine..
User-Maintenance
Instructions
Technical Service
Please call our Tool Hotline at
Fastener And Replacement Parts
Use only Arrow® T50® or equivalent staples.
Tool performance, safety and durability could be reduced if improper fasteners are used. When ordering replacement parts or fasteners, specify by part number.
Tool Repair
Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently..
Assembly Procedure For Seals
When repairing a tool, the internal parts must be cleaned and lubricated.. Parker
Storage
The stapler should be stored in a cool dry place..
Fasteners
Fasteners used in this stapler include:
•Arrow® T50® staples or any equivalent fastener with the approximate dimensions illustrated below..
1/4 inch - 9/16 inch
6mm - 14mm 1..3mm
10..7mm
9..3mm
0..7mm
www.chpower.com
5