Models NS219001, NS219500, NS319001 & NS349001

6. Remove nailer from work

surface. The Work

Contact

Element (WCE) must return to its original

down position. Pull the trigger. The nailer MUST NOT OPERATE. Do not use the tool if it operates while lifted from the work surface. Personal injury may result.

7.Pull the trigger and depress the work contact element (WCE) against the work surface. The nailer MUST OPERATE.

12

8.Depress the Work Contact Element (WCE) against work surface. Pull the trigger. The nailer MUST OPERATE.

12

LOADING THE NAILER

1.Always connect the tool to the air supply before loading fasteners.

2.Pull nail

pusher

Nail pusher

Latch

mechanism mechanism

 

back until

 

 

pusher

 

 

engages

 

 

with

 

 

magazine

 

 

latch.

 

 

3.Load strips of fasteners

into the magazine slot. Make sure that the nails are placed

into tool at the proper orientation.

4. Squeeze

the pusher and the latch together to

unlatch pusher. Make sure

the head of the last nail is under the head of the pusher.

UNLOADING THE NAILER

1. Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except always disconnect the air hose before unloading.

2. Pull nail

Nail pusher

Latch

pusher

mechanism

 

mechanism

 

 

 

back until

 

 

pusher

 

 

engages

 

 

with

 

 

magazine

 

 

latch.

 

 

3. Hold tool upright so nails will slide backwards toward magazine slot.

4.Squeeze the pusher

and latch together to unlatch the pusher once all nails have been removed.

ADJUSTING THE NAIL PENETRATION

The NS219001, NS319001 and NS349001 nailers are equipped with an adjustable depth of drive feature. This allows the user to determine how deep a fastener will be driven into the work surface.

1.Adjust the operating pressure to a pressure which will consistently drive the fasteners. Do not exceed the maximum operating pressure of the nailer of 120 psi.

2.To adjust the depth-of-drive, loosen the 4mm bolt on the top of nose. To increase depth, push WCE in toward nose as much as desired. Re-tighten bolt. To decrease depth, pull WCE out as much as desired. Re-tighten bolt.

3.Make sure that the trigger and work contact element (WCE) move freely up and down without binding or sticking after each adjustment.

ANTI-DRY FIRE

These tools are equipped with an Anti-Dry Fire feature. This prevents the WCE from being pushed in when only a few nails remain. Simply load new nail clip behind remaining nails to continue shooting.

ADJUSTING THE DIRECTION OF THE EXHAUST

The nailers are

 

equipped with

 

an adjustable

 

direction

 

exhaust

 

deflector. This

Rotate

is intended to

 

allow the user to change the direction of the exhaust. Simply twist the deflector to any direction desired.

CLEARING A JAM FROM THE NAILER

1. Disconnect nailer from air supply.

www.chpower.com