Operating Instructions

2. Remove all nails from

the magazine

(see Loading/ Unloading). Failure to do

so will cause the nails to eject from

the front of the tool.

3. Insert a

screwdriver intothe

nose of the tool. Push up

on the driver blade to free the jammed nail.

4. Grab the jammed nail with pliers and remove.

Technical Support

Please call our Nailer Hotline at 1-800- 543-6400 with any questions regarding the operation or repair of this nailer or for additional copies of this manual.

Fastener And Replacement Parts

Use only genuine

Campbell Hausfeld fasteners (or equivalent - see Fastener Interchange Information). Use only genuine Campbell Hausfeld replacement parts. Never substitute parts. Do not use modified parts or parts which will not give equivalent performance to the original equipment. Tool performance, safety and durability could be reduced. When ordering replacement parts or fasteners, specify by part number.

Nailer Repair

Nailer repairs must be performed by qualified and experienced service people ONLY.

Assembly Procedure For Seals

When repairing a nailer, the internal parts must be cleaned and lubricated. Parker O-lube or equivalent must be used on all o-rings. Each o-ring must be coated with O-lube before assembling. A small amount of oil must be used on all moving surfaces and pivots. After reassembling, a few drops of 30W non- detergent oil, or equivalent, must be added through the air line before testing.

www.chpower.com

6