Campbell Hausfeld SN268K00 Operating The, Cómo usar la, Sequential Trip Safety Mechanism, 21 Sp

Models: SN268K00

1 12
Download 12 pages 3.41 Kb
Page 4
Image 4
Operating The
150 psi WP
3/8” I.D.

Operating Instructions

Modelo SN268K00

Operating The

Stapler (Continued)

3. Use 3/8” air

hoses with a minimum

working pres- sure of 150 psi. Use 1/2”

air hoses for 50’ run or longer. For better performance, install a 3/8” quick plug (1/4” NPT threads) with an inside diameter of .315" (8mm) on the stapler and a 3/8” quick cou- pler on the air hose.

depressed. Do not operate the stapler if the WCE trip mechanism is not operating properly. Personal injury may occur.

1.Disconnect the air supply from the stapler.

2.Remove all

staples from Stapler (Continued)LOADING/UNLOADING THE STAPLERCómo usar lagrapadora (Continuación) the magazine QUE HACER CUANDO LA GRAPADORA TENGA UNA GRAPA ATASCADASequential Trip Safety MechanismOPERATING A SEQUENTIAL TRIP STAPLERADJUSTING THE STAPLEDEBE OPERAR. (See Loading-PARA AJUSTAR LA PENETRACION DE LAS GRAPAS Unloading).CHECKING THE WORK CONTACT ELEMENT (WCE)21 Sp

LOADING/UNLOADING THE STAPLER

1.

Always connect the tool to the air

 

supply before loading fasteners.

2.

Push down

Latch

 

on the latch

Button

 

button. Pull

 

 

back on the

 

 

magazine

 

 

cover.

 

3.For staples, load a clip of staples with the crowns straddling the magazine rail.

Cómo usar la

grapadora (Continuación)

4. Reconecte la grapadora a la fuente de su- ministro de aire.

5. Presione el Elemento de Contacto de Trabajo contra la superficie de

3.Para grapas, cargue una tira de grapas con las coronas montadas sobre el riel del cargador.

Carril del cargador

4. Empuje la tapa del cargador

QUE HACER CUANDO LA GRAPADORA TENGA UNA GRAPA ATASCADA

1. Desconecte la clavadora de la fuente de suministro de aire.

2. Remueva todos los clavos del depósito (vea Para Cargar /

4.Use a pressure regulator on the compressor, with an operating pres- sure of 0 - 125 psi. A pressure regu- lator is required to control the oper- ating pressure of the stapler between 60 and 100 psi.

Sequential Trip Safety Mechanism

This tool is equipped with a sequential trip safety mechanism. When the oper- ator depresses the Work Contact Element (WCE) against the work sur- face and then pulls the trigger, a fas- tener will be driven.

OPERATING A SEQUENTIAL TRIP STAPLER

1. Release trigger and place nose of tool against work surface.

2. Depress the

Work contact

element (WCE) against the

work surface and pull the trigger to

drive a fastener.

3. Release the trigger and lift the tool

3.

Make sure the

 

 

trigger and

 

 

Work Contact

 

 

Element (WCE)

movement

 

move freely up

 

 

 

and down

 

 

without stick-

 

 

ing or binding.

 

4.

Reconnect air

 

 

supply to the

 

 

stapler.

 

5.

Depress the

 

 

work contact

 

 

element

 

 

(WCE) against

 

 

the work sur-

 

 

face without

 

 

pulling the

 

 

trigger. The stapler MUST NOT

 

OPERATE. Do not use the stapler if

 

it operates without pulling the trig-

 

ger. Personal injury may result.

6.

Remove the

 

 

stapler from the

 

 

work surface.

 

 

The Work

 

 

Contact Element

 

 

(WCE) must

 

 

return to its original down position.

 

Pull the trigger. The stapler MUST

 

NOT OPERATE. Do not use the sta-

 

pler if it operates while lifted from

 

the work surface. Personal injury

 

may result.

 

Magazine rail

4. Push the magazine cover forward until latch button pops up.

5.Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except always disconnect the air supply before unloading.

ADJUSTING THE STAPLE

PENETRATION

1. Regulate the

air pressure to

60 psi at the

stapler.

2. Connect the air supply and test for

penetration by driving staples into a

sample piece of wood. If the staples

do not achieve the desired penetra-

tion, adjust the air pressure to a

higher setting until the desired pen-

trabajo sin

apretar el gatillo. La grapadora NO DEBE OPERAR. No use la herramienta si opera sin apretar el gatillo. Se pueden producir lesiones personales.

6. Remueva la

grapadora de la superficie

de trabajo. El Elemento de Contacto de

Trabajo tiene que volver a su posición original. La grapadora NO DEBE OPERAR. No use la herramienta si opera mientras está levantada de la superficie de trabajo.

7. Apriete el

gatillo y presione

el Elemento

de Contacto de Trabajo contra la superficie de trabajo. La grapadora

DEBE OPERAR.

PARA CARGAR Y DESCARGAR LA GRAPADORA

1.Siempre conecte la herramienta a la fuente de suminsitro de aire antes de colocarle los sujetadores.

hacia delante hasta que el botón del seguro salte hacia arriba.

5.Siempre descargue el sujetador antes de remover la herramienta de servicio. La descarga se hace siguiendo el proceso inverso de la carga; sin embargo, siempre se tiene que desconectar la manguera de aire antes de descargarla.

PARA AJUSTAR LA PENETRACION DE LAS GRAPAS

1. Regule la

presión de

aire en la

grapadora a

4,14 bar.

2. Conecte las mangueras de aire y

pruebe la penetración clavando

unas grapas en un pedazo de

madera. Si éstos no penetran hasta

el nivel deseado, aumente la

presión de aire y pruebe una vez

más, conmtinue haciendolo hasta

lograr los resultados deseados. La

presión de la grapadora no debe

exceder 690 bar ya que ésto

reduciría la durabilidad de la

grapadora.

Descargar la Clavadora). De lo contrario, hará que los clavos se expulsen desde la parte delantera de la clavadora cuando se remueve el conjunto de la boca.

3. Hale hacía adelante la lengüeta roja de la boquilla de desatasco rápido. Aleje la portezuela para

exponer y desatascar el sujetador atascado.

4.Vuelva a colocar la boquilla revertiendo la secuencia del paso 3.

5. Asegúrese que el

 

gatillo funciona y

 

que el Elemento

 

de Contacto de

movemiento

Trabajo se mueve

 

libremente hacia arriba y hacia abajo sin atascarse o pegarse.

from the work surface after each fastener is driven.

CHECKING THE WORK CONTACT ELEMENT (WCE)

Check the operation of the Work Contact Element (WCE) trip

mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being

7.Depress

the Work

Contact Manual backgroundManual backgroundManual backgroundManual background

Element Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background (WCE) Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background against

the work surface. Pull the trigger. The stapler MUST operate.

etration is achieved. Do not exceed

100 psi at the stapler or durability

of the stapler will be reduced.

2.Empuje hacia abajo sobre el boton del seguro. Mueva la tapa del cargador hacia atrás.

Botón del

seguro

www.chpower.com

4

21 Sp
Page 4
Image 4
Campbell Hausfeld SN268K00 Operating The, Cómo usar la, Sequential Trip Safety Mechanism, Stapler Continued, 21 Sp