Installation Requirements
To install a 4602 IP Telephone onto INDeX, the following items are required:
Power Socket: A switched 110-240V AC, 50-60Hz, 250-500mA supply
socket is required for each 4602 IP telephone.
LAN Socket: A 10/100Mbps RJ45 Ethernet LAN connection point is required
for each IP telephone.
Category 5 Cabling All LAN cables and LAN cable infrastructure used with
4602 IP Telephones must be Category 5 cabling.
LAN Cables: An RJ45 LAN cable is supplied with the 4602 IP Telephone for
connection to the Power Unit. This cable is fitted with an emc choke and
must be used as the connection between the Power Module and the 4602 IP
Telephone. You will also need an additional RJ45 (not supplied) LAN cable
for connection from the power unit to the customer LAN.
1151A1/B1 Power Unit: The A1 variant does not have an internal battery
and the B1 variant does. Neither unit is supplied with the 4602 and must be
purchased separately. Both unit supply power via the LAN cable to the 4602
IP telephone. The Power Unit can be replaced with a alternative LAN power
supply provided that the supply conforms to IEEE 802.3af.
Voice Compression Module: The IPNC must be fitted with a Voice
Compression Module. The size of the module will limit the number of
simultaneous VoIP calls.
DHCP Server: The IPNC can perform this role unless another DHCP server
already exists.
TFTP Server: The PC running the IPNC Manager application can perform
this role. The TFTP server is only required during 4602 IP telephone
installation and maintenance.
IPNC Manager PC: A PC running Manager is required for IPNC
configuration changes.
IP Telephone Software: The software for IP telephone installation is
supplied on the INDeX Administration CD and is part of the IPNC Manager
suite.
Licence Key: The 4602 IP telephones do not need a licence key to be
entered on the system.
Dynamic/Static Addressing
The 4602 IP Telephone can be configured on the LAN using either dynamic or
static addressing. Dynamic addressing is recommended. The procedures for
both are detailed in the following paragraphs.
4602 IP Telephone User PC Connection
The Power Unit has one Line input from the LAN and a Phone output to the
4602 IP Telephone as follows:
PHONE
RJ45 Socket
for connection to
4602 IP Telephone
LINE
RJ45 Socket
for connection to LAN
Socket for connection to mains
power supply at rea
r
1151B1 Power Unit
The PC's network configuration does not need to be altered from that which it
previously used for direct connection to the LAN.
INDeX 4602 IP Telephone Installation Manual Installation Procedure - Page 5
38DHB0002UKCQ – Issue 2 (11/06/2003) IPNC Setup