1
Models QS12 & QS24 Toth e Installer
050831
Section 1 To the Installer
This machine is designedfor indoor use only.
DO NOT install the machine in an area where
awat er jet could beus ed toc lean orrins e them achine.
Failure to follow this instruction may result in serious
electrical shock.

Air Clearance

Clearancesf rom the grill to other surfaces are requir ed
for proper air circulation:
The required minimum clearances from the grill to
combustible construction is: 4” (102 mm) bott om, 3”
(76 mm) rear, and 3” (76 mm) sides.
Bottom: 4 inches (102 mm) minimum
Rear: 3 inches (76 mm) minimum
Sides: 3 inches (76 mm) to combustible
surfaces
0 inches (0 mm) to non-combustible
surfaces;
0 inches (0 mm) between grills in multiple
installations.
Failure to comply with these minimum clearance
requirements will affect grill performance, and
may cause component damageand overheating
of combustible surfaces.

Electrical Connections

The QS Series grills have one electrical connection.
Check the data plate on the grill for voltage, cycle,
phase and electrical specifications. The power
connection is located behind the access line cover on
the front of the grill.
In the United States, this equipment isintended tobe
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70--1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Stationary appliances which are not equipped with a
power cord and a plug or other device to disconnect
the appliance from the power sourc e must have an
all--poledisconnect ing device with a contact gap of at
least 3 mm installed in the external installation.
This equipment is provided with a grounding lug
that is to be properly attached to the rear of the frame
by the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021 of
IEC 60417--1)on t herem ovable paneland t hef rame.
The proper wire size and fused circuit should be
selected according to grill data label information.
Incoming power must be connected to the terminals
with black characters on a white background, as
shown:
14092
Figure 1
CAUTION: DO NOT ATTEMPT TO USE
THE GRILL DURING A POWER OUTAGE. Grills
require electrical power for operation. In the ev ent of
a prolonged power outage, place the unit in the “OFF”
position.