To the Installer Models QS12 & QS24
Ventilation and Clearance
Toensure proper operation of thisappliance it must be
installed so that the products of combust ion are
efficiently removed. Do not store anything on top of the
grill.
Most service can be performed from the front of the
grill. When inspecting heating elements, the unit must
be disconnected and pulled out of the hood enclosure.
Allowfour feet in f ront of the appliance for t his purpose.
Leveling Procedures
Figure 2
Step 1
The leveling adjustment needs to be performed while
the grill is at operating temperature. Remove the cook
surface shroud and release sheet.
Step 2
Toallow adjustment of the gap pins, loosenthe two set
screws located on the side of the front and rear gap
slide.
Figure 3