Carrier 30MPA installation instructions Contents, General, Safety Considerations, a30-5029

Models: 30MPA

1 16
Download 16 pages 15.5 Kb
Page 1
Image 1
and COMFORTLINK™ Controls

AQUASNAP® 30MPA,MPW015-045 Liquid Chillers with Scroll Compressors

and COMFORTLINK™ Controls

Installation Instructions

CONTENTS

Page

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1,2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-16

Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Step 1 — Inspect Shipment . . . . . . . . . . . . . . . . . . . . 2

Step 2 — Position the Unit . . . . . . . . . . . . . . . . . . . . . 2

Step 3 — Place the Unit. . . . . . . . . . . . . . . . . . . . . . . . 7

Step 4 — Check Compressor Mounting . . . . . . . . 7 Step 5 — Make Piping Connections. . . . . . . . . . . . 7

30MPA SYSTEM CONDENSER

30MPW CONDENSER DESCRIPTION

30MPW CONDENSER

EVAPORATOR DESCRIPTION

EVAPORATOR PIPING

AIR SEPARATION

Step 6 — Fill the Chilled Water Loop. . . . . . . . . . .13

WATER SYSTEM CLEANING

FILLING THE SYSTEM

Step 7 — Make Electrical Connections. . . . . . . . .14

FLOW SWITCH

CONTROL BOX, POWER SECTION

CONTROL BOX, CONTROLS SECTION

CONTROL BOX, FIELD CONTROL WIRING SECTION

UNBALANCED 3-PHASE SUPPLY VOLTAGE

GENERAL

These installation instructions cover the 30MPA, MPW units with ComfortLink controls. The 30MPA units are condenserless units and the 30MPW units are all fluid cooled.

.

Installation Instructions WARNING

Electrical shock can cause personal injury and death. Shut off all power to this equipment during installation. There may be more than one disconnect switch. Tag all discon- nect locations to alert others not to restore power until work is completed.

a30-5029

Fig. 1 — 30MPA Unit

SAFETY CONSIDERATIONS

Installing, starting up, and servicing this equipment (Fig. 1 and 2) can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated struc- tures, etc.). Model number structure is shown in Fig. 3.

Only trained, qualified installers and service technicians should install, start up, and service this equipment.

When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment.

Follow all safety codes.

Wear safety glasses and work gloves.

Use care in handling, rigging, and setting bulky equipment.

a30-5030

Fig. 2 — 30MPW Unit

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Catalog No. 04-53300054-01

Printed in U.S.A.

Form 30MP-1SI

Pg 1

910

1-10

Replaces: New

Page 1