Carrier 38YSA instruction manual Programmable

Models: 38YSA

1 12
Download 12 pages 12.23 Kb
Page 6
Image 6
PROGRAMMABLE

CARRIER

FA, FB, FC,

PROGRAMMABLE

THERMOSTAT

FD, FF, FH

MODEL HP

FAN COIL

HEAT PUMP

CARRIER

 

 

ONE

PROGRAMMABLE

 

 

THERMOSTAT

FA, FB, FC, FD, FF, FH

HEAT

OUTDOOR

MODEL HP

FAN COIL

PUMP

THERMOSTAT

24 VAC HOT

R

R

 

INDOOR FAN

G

G

HEAT STAGE 2

W/W1

W2 *

 

COOL/HEAT

Y/Y2

E *

STAGE 1

W3 *

 

 

 

RVS COOLING

O/W2

 

NOT USED

Y1/W2

 

24 VAC COM

C

C

NOT USED

B

 

TROUBLE

L

* IF AVAILABLE

 

OPTIONAL

S1

 

OUTDOOR

 

 

SENSOR

S2

 

CONNECTION

 

R

Manual backgroundManual backgroundW2

Y

O

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC HOT

 

R

 

 

 

 

 

 

 

 

INDOOR FAN

 

G

 

 

 

 

 

 

 

 

 

HEAT STAGE 2

 

W/W1

 

COOL/HEAT

 

 

 

 

 

 

 

Y/Y2

 

STAGE 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RVS COOLING

 

 

 

O/W2

 

NOT USED

 

 

 

 

 

 

Y1/W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC COM

 

C

 

 

 

 

 

 

 

 

NOT USED

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLE

 

 

L

 

 

 

 

 

 

 

 

 

OPTIONAL

 

 

 

S1

 

OUTDOOR

 

 

 

 

 

SENSOR

 

 

 

 

 

 

CONNECTION

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W3

R

G

W2

E

C

R

 

W2

ODT

 

Y

O

C

A97534

NOTE: Remove wires from crimp nut in indoor fan coil when installing outdoor thermostat.

IMPORTANT: When using outdoor thermostat, W2 must be energized when requesting supplemental heat.

A97535

CARRIER

FA, FB, FC,

 

TWO

PROGRAMMABLE

 

THERMOSTAT

FD, FF, FH

HEAT

OUTDOOR

MODEL HP

FAN COIL

PUMP

THERMOSTATS

24 VAC HOT

INDOOR FAN

 

W3

ODT

R

 

 

 

EHR

R

R

G

 

 

 

G

 

CARRIER

 

 

PROGRAMMABLE

40FKA

 

THERMOSTAT

FK4C

HEAT

MODEL HP

FAN COIL

PUMP

HEAT STAGE 2

COOL/HEAT STAGE 1

RVS COOLING

NOT USED

24 VAC COM

NOT USED

TROUBLE

OPTIONAL OUTDOOR SENSOR CONNECTION

W/W1

 

 

 

W2

W2

Y/Y2

 

 

 

O/W2

 

Y

 

 

EHR

 

O

Y1/W2

 

 

 

 

E

ODT

 

 

C

EHR

 

 

C

B

C

 

 

L

 

 

S1

 

 

S2

 

 

 

 

 

 

 

24 VAC HOT

 

R

 

 

 

INDOOR FAN

 

G

 

 

 

 

 

HEAT STAGE 2

 

W/W1

COOL/HEAT

 

 

 

 

Y/Y2

STAGE 1

 

 

 

 

 

 

 

 

 

 

RVS COOLING

 

 

O/W2

NOT USED

 

 

 

 

Y1/W2

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC COM

C

 

 

 

NOT USED

B

 

 

 

TROUBLE

L

 

 

 

 

 

DH J1 JUMPER

RManual backgroundManual backgroundManual background R

G

W1

W2

W2

J2 JUMPER

 

Y/Y2

Y

O

O

C

C

Y1

 

NOTE: Remove wires from crimp nut in indoor fan coil when installing outdoor thermostats.

IMPORTANT: When using outdoor thermostats, W2 must be energized when requesting supplemental heat.

A97536

 

 

 

 

OPTIONAL

 

S1

OUTDOOR

 

 

SENSOR

 

 

 

CONNECTION

 

S2

 

 

 

 

A98629

Fig. 9—Typical 24-v Circuit Connections using Carrier Model HP Thermostat with Fan Coils

and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats

6

Page 6
Image 6
Carrier 38YSA instruction manual Programmable