Table 1 — Physical Data

UNIT SIZE

03

06

08

10

12

15

18

21

25

UNIT WEIGHTS (lb)*

 

 

 

 

 

 

 

 

 

39LA

200

280

411

470

540

620

695

740

820

39LB

150

210

308

352

405

465

521

555

615

39LC

170

238

349

400

459

527

590

629

697

39LD

230

322

472

540

621

713

799

851

943

39LF

230

322

472

540

621

713

799

851

943

39LG

120

168

246

282

324

372

417

444

492

39LH

220

308

452

517

594

682

764

814

902

COMPONENT WEIGHTS (lb)

 

 

 

 

 

 

 

 

 

Mixing Box Section

139

164

193

219

226

244

283

272

311

Filter Mixing Box

150

173

208

227

245

279

327

340

395

Angle Filter Section

75

82

97

107

114

134

140

159

185

Flat Filter Section

37

43

48

50

55

74

75

86

90

Access Section

48

55

60

64

68

74

77

87

92

Preheat (Water) Section

36

42

43

46

49

52

54

53

57

Preheat (Electric) Section

49

56

61

66

72

74

76

87

89

TYPICAL DRY COIL WEIGHTS (lb)

 

 

 

 

 

 

 

 

 

Large Face Area Cooling Coils,

 

 

 

 

 

 

 

 

 

1/2-in. OD (Chilled Water & DX)†

56

84

98

109

137

178

198

251

280

4-Row

6-Row

63

95

123

138

174

234

270

327

363

Small Face Area Cooling Coils,

 

 

 

 

 

 

 

 

 

1/2-in. OD (Chilled Water & DX)†

45

72

91

105

133

161

182

211

238

4-Row

6-Row

53

85

113

129

162

197

225

270

307

8-Row

61

92

129

143

189

228

263

324

377

Hot Water Coils, 1/2-in. OD†

19

34

38

48

58

62

77

86

95

1-Row

2-Row

28

43

51

61

76

89

104

117

130

Steam Coils, 1-row, 1-in. OD

 

 

 

 

 

 

 

 

 

6-FPI

50

70

85

95

110

135

150

180

215

9-FPI

55

80

100

115

125

155

175

214

256

12-FPI

60

85

115

130

145

180

205

248

297

FAN

91/2

125/8

125/8

 

 

181/8

 

 

 

Wheel Diameter (in.)

15

15

20

20

25

Wheel Width (in.)

71/8

91/2

111/8

111/8

15

15

131/2

18

15

Shaft Diameter (in.)

3/4

13/16

13/16

13/16

13/16

17/16

17/16

17/16

111/16

Maximum Fan Rpm

2500

2000

2000

1600

1600

1400

1300

1100

1000

OPERATING CHARGE, R-22 (lb)

 

 

 

 

 

 

 

 

 

4-Row Coil

1-2

2-3

3-4

4-5

4-5

5- 6

6- 7

6- 8

6- 9

6-Row Coil

1-2

2-4

5-6

5-6

6-8

8-10

9-11

11-13

11-16

8-Row Coil

2-3

3-5

5-6

5-7

7-9

10-12

12-14

13-19

16-24

COIL VOLUME (gal. water)

 

 

 

 

 

 

 

 

 

Chilled Water, 1/2-in. OD Tube,

 

 

 

 

 

 

 

 

 

Large Face Area

 

 

 

 

 

 

 

 

 

4-Row

2.5

3.5

4.5

5.2

5.6

7.3

8.5

10.4

12.0

6-Row

3.2

4.7

6.0

6.8

7.7

10.1

11.7

14.2

16.3

Chilled Water, 1/2-in. OD Tube,

 

 

 

 

 

 

 

 

 

Small Face Area

 

 

 

 

 

 

 

 

 

4-Row

2.1

3.3

3.9

4.1

5.1

6.3

7.3

8.7

9.8

6-Row

2.4

3.7

5.1

5.9

6.6

8.3

9.5

11.8

13.5

8-Row

2.7

4.1

6.4

7.4

8.4

10.7

12.1

14.7

17.2

Hot Water, 1/2-in. OD Tube

0.5

0.8

1.0

1.3

1.5

1.8

2.1

2.5

2.9

1-Row

2-Row

0.7

1.3

1.6

2.0

2.4

2.9

3.4

4.0

4.8

COOLING COILS

 

 

 

 

 

 

 

 

 

Chilled Water 1/2-in. OD Tube,

 

 

 

 

 

 

 

 

 

(4, 6 Row) Large Face Area

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

3.63

5.90

7.90

9.54

11.18

14.91

17.71

21.6

25.0

Number of Tubes/Face

16

20

24

24

24

32

38

38

44

Finned Tube Length (in.)

26.1

34.0

37.9

45.8

53.7

53.7

53.7

65.5

65.5

Chilled Water 1/2-in. OD Tube

 

 

 

 

 

 

 

 

 

(4, 6, 8 Row) Small Face Area

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

2.72

4.72

6.58

7.95

9.32

12.12

13.98

17.1

20.5

Number of Tubes/Face

12

16

20

20

20

26

30

30

36

Finned Tube Length (in.)

26.1

34.0

37.9

45.8

53.7

53.7

53.7

65.5

65.5

DX 1/2-in. OD Tube

 

 

 

 

 

 

 

 

 

(4, 6 Row) Large Face Area

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

3.63

5.90

7.90

9.54

11.18

14.91

17.71

21.6

25.0

Finned Tube Length (in.)

26.1

34.0

37.9

45.8

53.7

53.7

53.7

65.5

65.5

DX 1/2-in. OD Tube

 

 

 

 

 

 

 

 

 

(4, 6, 8 Row) Small Face Area

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

2.72

4.72

6.58

7.95

9.32

12.12

13.98

17.1

20.5

Finned Tube Length (in.)

26.1

34.0

37.9

45.8

53.7

53.7

53.7

65.5

65.5

HEATING COILS

 

 

 

 

 

 

 

 

 

Hot Water 1/2-in. OD Tube,

 

 

 

 

 

 

 

 

 

U-Bend (1, 2 Row)

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

2.72

4.72

6.58

7.95

9.32

12.12

13.98

17.1

20.5

Number Tubes/Face

12

16

20

20

20

26

30

30

36

Finned Tube Length (in.)

26.1

34.0

37.9

45.8

53.7

53.7

53.7

65.5

65.5

Steam 1-in. OD (1 Row)

 

 

 

 

 

 

 

 

 

Face Area (sq ft)

2.13

4.18

6.22

7.53

8.85

11.06

13.28

16.2

18.9

Number Tubes/Face

4

6

8

8

8

10

12

12

14

Finned Tube Length (in.)

25.5

33.4

37.3

45.2

53.1

53.1

53.1

53.1

64.9

LEGEND

*Less coil.

DX — Direct Expansion

†Coils have 14 aluminum fins per inch on copper tubes.

 

FPI — Fins Per Inch

 

6

Page 6
Image 6
Carrier 39LH03-25, 39LB, 39LD, 39LA, 39LC, 39LE, 39LF, 39LG specifications Physical Data, Unit Size

39LG, 39LH03-25, 39LD, 39LE, 39LB specifications

The Carrier 39 series, encompassing models 39LA, 39LF, 39LC, 39LB, and 39LE, represents a prominent line of rooftop packaged units that combine robust performance, energy efficiency, and advanced technology for commercial applications. Designed to provide reliable heating and cooling solutions, these units stand out for their versatility and innovative features.

The 39LA model offers high efficiency and flexibility, making it ideal for various building types. It incorporates advanced economizer capabilities that enhance indoor air quality while reducing energy costs. The unit is equipped with a dual-walled cabinet, which not only improves durability but also ensures quiet operation, making it suitable for noise-sensitive environments.

The 39LF model further enhances energy savings, featuring a unique hybrid heat pump system. This system allows for both heating and cooling through an integrated design, reducing the need for separate systems and streamlining maintenance requirements. The 39LF also boasts high Seasonal Energy Efficiency Ratio (SEER) ratings, contributing to lower operating costs without compromising comfort.

The 39LC variant excels in humid climates, employing advanced dehumidification technologies that effectively manage indoor moisture levels. This model is often utilized in environments such as gyms, restaurants, and hotels where humidity control is vital. Its variable-speed compressors adjust output based on demand, optimizing energy consumption while maintaining consistent comfort levels.

The 39LB model focuses on enhanced filtration and air quality improvements. Its engineered design accommodates high-efficiency particulate air (HEPA) filters, crucial for spaces that require stringent air quality standards. This model also includes smart controls that allow for precise temperature adjustments, ensuring optimal comfort in any setting.

Finally, the 39LE unit emphasizes user-friendly interfaces and smart technology integration. The built-in Wi-Fi capability enables remote monitoring and operation, allowing managers to adjust settings from anywhere, improving overall energy management. Additionally, the 39LE’s compatibility with Building Management Systems (BMS) facilitates seamless integration into existing setups.

In summary, the Carrier 39 series 39LA, 39LF, 39LC, 39LB, and 39LE present a comprehensive array of features designed for various commercial heating and cooling applications. With an emphasis on energy efficiency, advanced air quality management, and user-friendly technology, these units continue to set the standard for rooftop packaged units in the industry. Their innovative characteristics not only enhance comfort but also promote sustainability, making them a smart choice for modern commercial environments.