CONTROL SELECTION GUIDE
Use this guide to make sure that all necessary components are provided for and that the components are compatible with the required control system.
NOTE: When thermostatic fan control is selected or when unit outside air dampers are used,
|
|
|
| CHANGEOVER |
| FAN |
| |
| SYSTEM | DESCRIPTION | THERMOSTAT | ON | VALVE | NOTES | ||
| SWITCH (SW) | |||||||
|
|
|
| SUPPLY PIPE |
|
| ||
|
|
|
|
|
|
| ||
| Fan | Fan manually cycled | None | None | None | Standard | Not recommended | |
| Control |
|
|
|
| for high humidity | ||
|
|
|
|
|
| application | ||
| Thermostat cycles fan | Wall mounted | None | None | Thermostat has | |||
|
|
| ||||||
|
| from speed set with | includes |
|
| integral |
| |
|
| fan switch. | switch. |
|
|
| ||
|
| Thermostat cycles fan | Wall mounted. | Yes | None | Standard | Unit mounted | |
|
| from fan speed set | Heating/cooling |
|
| thermostats provide | ||
|
| with switch. Mode | Thermostat |
|
|
| very poor room | |
| automatically switched |
|
|
|
| temperature control | ||
| by changeover |
|
|
|
|
| ||
| sensing water temp. |
|
|
|
|
| ||
| Thermostat cycles fan from | Wall or unit | Yes | None | No Standard | Best fan cycle | ||
| high to low on cooling | mounted |
|
| control for | |||
| and low to off on heating. |
|
|
| high humidity | |||
HEATING |
|
|
|
| ||||
|
|
|
|
| only | applications | ||
Two- | Thermostat cycles valve | Wall mounted | None | Motorized (N.C.) | Thermostat | Valve packages | ||
position | open or closed. | includes |
| has integral | with belled end(s) | |||
electric |
| switch. |
| no bypass required. | for ®eld soldering | |||
PIPE | valves |
|
|
|
|
| to coil. | |
Thermostat cycles valve | Wall or unit | Yes | Motorized (N.C.) | Standard | ||||
| ||||||||
open or closed. | mounted. |
|
| |||||
2- |
| Mode automatically | Heating/cooling |
|
| Others have |
| |
|
|
|
|
| ||||
|
| switched by changeover | Thermostat |
|
| thermostats with |
| |
|
| sensing water temp. |
|
|
| integral |
| |
| Pneumatic | Thermostat modulates | By others. | By others. | 2- and | Standard | Factory assembled | |
| modulating | pneumatic control valve. |
|
| furnished by others. | in valve package | ||
| valves |
|
|
| Can be equipped |
| w/¯are nuts. | |
|
|
|
| with factory |
| Valve packages | ||
|
|
|
|
| assembled |
| with belled end(s) | |
|
|
|
|
| valve package. |
| for ®eld soldering | |
|
|
|
|
|
|
| to coil. | |
| Two- | Thermostat cycles valve | Wall or unit | Yes. | Motorized | Standard | Valve packages | |
| position | open or closed. 2° F after | mounted. Sequenced | Two Required. | with belled end(s) | |||
| electric | valve closes, thermostat | heating and cooling. |
|
| Others have | for ®eld soldering | |
| valve with | activates electric heater. |
|
|
| thermostats with | to coil. | |
| Auxiliary | Heater can't turn on |
|
|
| integral |
| |
| Electric | if hot water is in coil. |
|
|
|
|
| |
| Heat |
|
|
|
|
|
| |
| Thermostat cycles valve | Wall mounted | None | Motorized | Thermostat | Valve packages | ||
| ||||||||
| open or closed. Manual | includes |
| has integral | with belled end(s) | |||
|
|
| ||||||
|
| changeover switch | switch. |
| no bypass required | for ®eld soldering | ||
|
| changes thermostat to |
|
|
|
| to coil. | |
HEAT |
| heat to activate electric |
|
|
|
|
| |
| heater. |
|
|
|
|
| ||
Two- | Thermostat cycles valve | Wall mounted | None | Motorized (N.C.) | Thermostat | Valve packages | ||
ELECTRIC | position | open or closed. | includes |
| has integral | with belled end(s) | ||
electric | Manual changeover switch | switch. |
| no bypass required | for ®eld soldering | |||
valve with | changes thermostat to heat |
|
|
|
| to coil. | ||
total | to activate electric heater. |
|
|
|
|
| ||
electric |
|
|
|
|
|
| ||
Thermostat cycles valve | Wall or unit | None | Motorized (N.C.) | Standard |
| |||
| heat | open or closed. | mounted. |
|
| |||
|
|
| ||||||
| 2° F after valve closes, | Sequenced heating |
| no bypass required |
|
| ||
|
|
|
|
| ||||
|
| thermostat activates | and cooling |
|
|
|
| |
|
| electric heater. |
|
|
|
|
| |
| Pneumatic | Thermostat modulates | By others. | By others. | 2- and | Standard | Factory assembled | |
| modulating | pneumatic control valve. |
|
| furnished by others. | in valve package | ||
| valves | After changeover, |
|
| Can be equipped |
| w/¯are nuts. | |
| thermostat |
|
| with factory |
| Valve packages | ||
|
| activates electric heater. |
|
| assembled |
| with belled end(s) | |
|
|
|
|
| valve package. |
| for ®eld soldering | |
|
|
|
|
|
|
| to coil. | |
| Two- | Thermostat cycles | Wall mounted | None | Motorized (N.C.) | Thermostat | Valve packages | |
| position | cooling and heating | includes subbase |
| has integral | with belled end(s) | ||
| electric | valves open or closed. | with |
| (requires 2 valves) | for ®eld soldering | ||
| valves |
| switch. |
|
|
| to coil. | |
|
|
|
|
|
|
| ||
| Thermostat cycles cooling | Wall or unit | None | Motorized (N.C.) | Standard |
| ||
|
|
| ||||||
|
| valve open or closed. 2° F | mounted. |
|
| |||
PIPE |
| after valve closes, | Sequenced heating |
| (requires 2 valves) | Others have |
| |
| thermostat cycles | and cooling. |
|
| thermostats |
| ||
| heating valve open or closed. |
|
|
| with integral |
| ||
4- |
|
|
|
|
|
| ||
| Pneumatic | Thermostat modulates | By others. | By others. | 2- or | Standard | Factory assembled | |
| modulating | cooling valve. |
|
| furnished by others. | in valve package | ||
| valves | After changeover, |
|
| Can be equipped |
| w/¯are nuts. | |
| thermostat modulates |
|
| with factory |
| Valve packages | ||
|
| heating valve. |
|
| assembled |
| include unions for | |
|
|
|
|
| valve package. |
| for ®eld assembly | |
|
|
|
|
|
|
| to coil. |
*If system is
NOTE:
3