Carrier 58MVC A Check-Upchecklist, Upper Inducer Housing Drain, Unit And Property Damage Hazard

Models: 58MVC

1 14
Download 14 pages 55.61 Kb
Page 12
Image 12
Fig. 35 - Upper Inducer Housing Drain

A06456

Fig. 35 - Upper Inducer Housing Drain

Connection Cap

3.Remove main furnace door. (See Fig. 19.)

4.Remove upper inducer housing drain connection cap. (See Fig. 35.)

5.Connect field-supplied 1/2-in. ID tube to upper inducer housing drain connection.

6.Insert field-supplied funnel into tube.

7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze

should run through inducer housing, overfill condensate trap, and flow into open field drain. (See Fig. 36.)

A06457

Fig. 36 - Pour Antifreeze

8.Remove funnel and tube from inducer housing and replace

drain connection cap and clamp.

9.Replace main furnace door. (See Fig. 30.)

10.Propylene glycol need not be removed before restarting furnace.

UNIT AND PROPERTY DAMAGE HAZARD

Failure to follow this warning could result in damage to unit components.

This furnace is designed for continuous return-air

minimum temperature of 60°F (15.6°C) db or intermittent

operation down to 55_'F (12.8°C) db, such as when used

with a night setback thermostat. Return-air temperature nmst not exceed 85"F (29.4°C) db.

If you choose to leave your furnace on during extended absences

do not set your thermostat lower than the limits shown in the Caution box above.

To protect your property from damage from potential problems

due to unintended interruptions in utility services or other events.

it is recommended that you either winterize your plumbing

system or have someone check on your house regularly while you are away.

Your dealer or a licensed plumber can give you additional advice

about winterizing your plumbing system.

A CHECK-UP CHECKLIST

Your furnace represents an important investment in your family's

comfort and your home's value. To keep it performing properly

and to prevent future problems, have a trained service specialist

give your furnace a professional check-up annually. The following checklist can be used as a guideline to proper service:

Inspect all flue gas passages, burners, heat exchangers, coupling box(es), and inducer assembly.

Inspect all combustion-air and vent piping inside

structure and vent pipe termination outside the structure.

Check gas pipes leading to and inside your furnace for leaks.

Inspect and clean the blower motor and wheel.

NOTE: The inducer and blower motors are pro-lubricated and

require no additional lubrication. These motors can be identified by the absence of oil ports on each end of the motor.

Inspect and change or clean air filters(s), if necessa U.

Inspect all supply- and return-air ducts for

obstructions, air leaks, and insulation. Remedy any problem when necessary.

Inspect the return-air duct connections(s) at the furnace to ensure it is physically sound, sealed to the furnace casing, and terminates outside the space containing the furnace.

Inspect electrical wiring, connections, and components for loose connections.

Perform an operational checkout to determine whether your furnace is working properly and if it requires adjustments.

Inspect all condensate drain tubes and condensate trap

assembly for leaks. The condensate removal system should be cleaned annually by a qualified service agency. Refer to the Service and Maintenance Instructions for further information.

Examine the physical support of the furnace. Support should be sound with no cracks, sagging, gaps. etc. around the base.

Check furnace for any obvious signs of deterioration.

12

Page 12
Image 12
Carrier 58MVC owner manual A Check-Upchecklist, Upper Inducer Housing Drain, Unit And Property Damage Hazard