Step 1 Select the Best Location

A. Your room air conditioner was designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe and proper installation.

B. Make sure window and frame is structurally sound and free from dry and rotted wood.

C.For maximum efficiency, install the air conditioner on side of the house or building which favors more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.

D.Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit (see Fig. 5). The rear of the unit should be outdoors and not in a garage nor inside of a building. Keep unit as far away as possible from obstacles and obstructions and at least 30” above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.

E.Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at proper current (see table 1 on page 4). All wiring should be in accordance with local and national electrical codes.

F.Your unit was designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause the basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties.

Awning

20”

Min.

12” Min.

 

 

20”

 

 

Min.

 

 

Fence,

 

30” Min.

wall, or

Side

other

 

obstruction

 

obstacle.

Ground

A06534

Fig. 5 ---Air Conditioner Clearances

Window Opening Requirements

SIZE

MODEL

 

 

12K

14K---23K

 

 

 

 

Cabinet Size

22.8”/15.7”/24.1”

26.5”/18.5”/26.9”

(W/H/D)

 

 

 

 

 

Window Opening

27” --- 41”

30” --- 44”

Width

 

 

 

 

 

Window Opening

16”

18.5”

Height

 

 

 

 

 

Step 2 Preparation to Remove the Air Conditioner Slide-Out Chassis

A.Remove total of (4) Philips screws securing the chassis to the cabinet. There are (2) screws on each side. The set of screws closest to the front of the unit secure the front panel to the cabinet. The set of screw closest to the rear of the unit secure the cabinet to the chassis (see Fig. 6).

B.Remove the front panel assembly from the cabinet by gently pulling it.

C.Grasp the pull handle at the front of the slide-out chassis and carefully slide the air conditioner out of the cabinet (see Fig. 7). NOTE: Screws must be reinstalled upon completion of the window installation to secure slide-out chassis.

IMPORTANT: Please seek assistance for this procedure.

A06535

Fig. 6 ---Screw Removal

Coil

Chassis

Pull Handle

A06536

Fig. 7 ---Air Conditioner Removal

Step 3 Assembly of the upper & lower channels to the cabinet

A.” L” Shaped Top Channel: Stick the double adhering seal to the ” L” shaped top channel, and then Install the ”L” shaped top channel to the cabinet as shown in Fig. 8 using (5) 1/4” screws.

B.”n” Shaped Bottom Channel installed as shown in Fig.8 using

(4)1/4” screws.

6

Page 6
Image 6
Carrier KH_123P manual Installation Instructions, Personal INJURY/UNIT Operation Hazard, Select the Best Location, Ground

KC_141P, KH_233P, KC_223P, KC_233P, KC_183P specifications

Carrier has made significant strides in the HVAC industry with its innovative series of air conditioning systems, particularly the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P models. These models are a testament to Carrier's commitment to delivering advanced technology, energy efficiency, and enhanced comfort in climate control.

The KH_123P model is a compact ductless system that provides effective cooling and heating solutions for residential spaces. With its sleek design, it seamlessly integrates into any home decor. The unit features advanced inverter technology, allowing for variable speed operation that adjusts to the cooling demand, significantly reducing energy consumption. It also boasts low ambient cooling capability, making it ideal for use in various climates.

Next, the KC_183P and KC_233P models are designed for medium to large spaces, providing powerful climate control with a focus on quiet operation. Both models are equipped with high-efficiency scroll compressors that ensure reliable performance while minimizing noise levels. Additionally, these units feature multiple fan speeds and advanced air filtration systems, which improve indoor air quality by capturing dust, allergens, and other pollutants.

The KC_223P model stands out for its smart technology integration. It supports Wi-Fi connectivity, allowing users to control the system remotely via a smartphone app. This feature enables scheduling, temperature adjustments, and monitoring of energy usage from virtually anywhere. The KC_223P also includes precise temperature control and zoning capability, creating comfort zones tailored to individual preferences throughout the home or office.

The KH_233P model further enhances energy efficiency with its EcoMode setting, which optimizes performance for lower energy consumption during periods of low activity. This model is also equipped with advanced diagnostics and self-cleaning functions, reducing maintenance needs and extending the unit's lifespan.

All of these Carrier models come with a robust warranty and are backed by Carrier’s storied reputation for quality and innovation. With their blend of advanced technology, efficiency, and user-friendly features, the KH_123P, KC_183P, KC_233P, KC_223P, and KH_233P systems are stellar choices for anyone looking to enhance their indoor climate comfort. Carrier continues to set the standard in the HVAC sector through these versatile and high-performing solutions.