Carrier Access EdgeFLEX, 600 installation manual Installing the Decorative Bezel, Connecting Power

Models: 600 EdgeFLEX

1 54
Download 54 pages 436 b
Page 25
Image 25

EdgeFLEX 600 Installation

Installing the Decorative Bezel

Installing the Decorative Bezel

A decorative bezel is included in the Accessory Kit to cover the fan tray and air filter. Snap the bezel onto the ball stud as shown in the following illustration.

Connecting Power

DANGER! BEFORE INSERTING OR EXTRACTING A EDGEFLEX 600 DC POWER SUPPLY UNIT, ENSURE THAT THE PSU’S CIRCUIT BREAKER SWITCH IS IN THE OFF POSITION, AND THAT THE DC

POWER CONNECTOR HAS BEEN UNPLUGGED.

Requirements for DC Power Connections

The EdgeFLEX 600 DC model can be powered from a DC supply operating between -40 and -72 VDC. The power connector is located on the front of the Power Supply Module(s), which are located in the top two slots of the EdgeFLEX 600 chassis. The PSU modules are redundant and hot-swappable.

Use a separate circuit breaker to power each power supply. This will allow one power supply to keep the EdgeFLEX 600 operating while the other power supply is powered down for maintenance.

Use 7 to 8 gauge wire for up to 50 foot run to power the device. Use a circuit breaker rated for 25 Amps for the power leads.

EdgeFLEX 600 - Release 2.0

2-7

Page 25
Image 25
Carrier Access EdgeFLEX, 600 Installing the Decorative Bezel, Connecting Power, Requirements for DC Power Connections