Battery Charge Block

Table 2.17

 

 

 

Item

 

Specification

Remark

Charge control

 

 

 

 

 

Output voltage

 

 

DC4.22V±30mV

 

 

Charge current (standard mode)

 

DC1,600mA±10%

 

 

Charge current (standby mode)

 

DC160±40mA

 

 

Full charge detection current

 

DC120±30mA

 

 

Voltage control

Full charge detection voltage

4.1V

 

 

 

 

Re-charge detection voltage

4.0V

 

 

Re-charge detection

voltage

 

DC4.0±0.1V

 

 

Input voltage

 

 

DC8.0 to 20V

 

 

Timer

 

 

 

 

 

 

Charge timer (standby mode)

 

90 minutes

 

 

 

Charge timer (standard mode)

 

720 minutes

 

 

 

Trickle charge timer

 

120 minutes

 

 

Charge hour

 

 

 

 

 

 

HA-A20BAT

Approx. 2.5 hours (for 1 pack)

At 0 to 40 ºC

 

 

 

 

Approx. 5.0 hours (for 2 packs at same time)

 

 

 

DT-5025LBAT

Approx. 5.0 hours (for 1 pack)

At 0 to 40 ºC

 

 

 

 

Approx. 10.0 hours (for 2 packs at same time)

 

 

Temperature control

Not available

 

 

No. of charge outputs

1

 

 

Operation mode

 

 

 

 

 

Battery pack mount detection

 

 

 

 

 

Battery pack not mounted

LED OFF, charge output OFF

 

 

 

Battery pack mounted

LED ON in red, charge output OFF

 

 

Check

on battery pack

LED ON in red, charge output OFF

 

 

Battery charge (standby mode)

LED ON in red, charge output ON

 

 

Battery charge (standard mode)

LED ON in red, charge output ON

 

 

Wait mode in trickle charge

LED ON in green, charge output OFF

 

 

Charge in trickle mode

LED ON in green, charge output ON

 

 

Charge completed

LED ON in green, charge output OFF

 

 

Charge abnormal end

LED flash in red, charge output OFF

 

Other

 

 

 

 

 

 

Priority order of battery charging

Order in mounted order

 

Weight/Dimensions

Table 2.18

Item

Specification

Remark

Weight

Approx. 154 g

 

Dimensions

100 (L) x 110 (W) x 49 (H) mm

 

33

Page 33
Image 33