Scanning PLU

Product barcodes are read by scanning with hand-held scanner, and are filed in the scanning PLU file together with the unit price, item descriptor, programming status, link department, totalizer and counter.

When a barcode is entered by scanning, or from the keyboard by using <OBR> (OBR key) or <One touch NLU> (One touch NLU key) and it has been filed in the scanning PLU file, the preset unit price is accumulated to its own totalizer and other appropriate totalizers.

Scanning PLUs include UPC-A/UPC-E/EAN-13/EAN-8, source marking, in-store marking code.

Item registration

By scanner/code input/one touch NLU key

OPERATIONRECEIPT

Item 1

Scan-PLU

($2.35)

“Scanning”

REG

03-04-2000 18:45

 

—————————

 

 

C01

MC#01

000170

 

(scan)

PLU code

49012347

 

 

 

 

 

 

 

—————————————

Scan-PLU

($2.00)

123

1 Scan-PLU01

•2.34

 

 

 

Item 2

—————————

 

#49012347

Scanning PLU code *1

(code)

PLU code

123456

456OBR

1 Scan-PLU02

•2.00

 

—————————————

Scan-PLU

($1.23)

Scanning-PLU code and

#123456

 

 

 

 

 

 

 

 

 

 

Item 3

—————————

 

OBR key

1 Scan-PLU03

•1.23

 

(OTN)

PLU code

49012354

NLU

#49012354

 

 

—————————————

 

 

 

 

 

 

 

 

B

TL

•5.58

 

Payment

Cash

$5.58

One touch NLU

CASH

•5.58

*1 Programmable option

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not found PLU

When a scanning PLU item which does not exist in the scanning PLU file is registered, an error occurs (Item not found error). In this case, you can input this item to the ECR and register it at the same time. After this operation, “Item not found error” does not occur during the next registration.

OPERATIONRECEIPT

Advanced Operations

 

Scan-PLU ($1.00)

 

—————————

 

Item 1

PLU code 49012361

(scan)

—————————

 

—————————————

Dept.

1

Scan-PLU ($1.00)

 

Item 2

—————————

 

(scan)

PLU code 49012361

—————————————

 

 

Payment

Cash

$2.00

“Scanning”

Does not exist in the scanning PLU file

“Not Found Error”100!

Input price and press the linked department key.

“Scanning”

Register normally.

REG

03-04-2000 18:50

 

C01

MC#01

000171

 

1

DEPT01

 

•1.00

Link department

 

#49012361

 

 

descriptor/amount

1

DEPT01

 

•1.00

 

 

#49012361

 

 

 

 

TL

 

•2.00

 

 

CASH

 

•2.00

 

 

 

 

 

 

 

F

After daily operation, a “Not found PLU maintenance” is necessary to merge not found PLU(s) into the scanning PLU file. Please consult with your dealer in detail.

TK-7000/7500 User’s Manual