E
17
1.Loosen and remove the 8 screws at the back of the transmitter, and take the cover (Fig.
27).
2.Load a new battery (CR2032) with the (+) pole upward. Fix the packing carefully into the
cover, and place it back on the transmitter body. Fasten the screws securely.
Caution: If the packing is not fixed correctly, it will deteriorate waterproof system.
Replacing Electrode Belt
The electrode belts may deteriorate after long term use. When function errors occur occa-
sionally, replace the electrode belts with the new one according to the following instruction.
1.Loosen and remove the 8 screws at the back of the transmitter, and take the cover (Fig.
28).
2.Pull the electrode belts upward, which are placed on the right and left of the transmitter.
3.Fix the new belts onto the transmitter, with the electrode part downward.
4.Fix the packing carefully into the cover, and place it back on the transmitter body. Fasten
the screws securely.
Caution: If the packing is not fixed correctly, it will deteriorate waterproof system.
Spare Accessories
#169-9820 Electrode Belt
#169-9835 Wrist Band
#169-6567 Bracket Sensor Kit
#169-6562 Bracket Sensor Kit (Long)
#169-9730
Heavy Duty Wire and Bracket Sensor Kit
#169-9810 Attachment Belt
#169-9800 Wireless Heart Rate Sensor Kit
#169-9840 Attachment Kit
#169-6280 Universal Sensor Band
#166-5120 Wheel Magnet
#166-5150 Lithium Battery (CR2032)
Wireless Heart Rate Sensor
for CC-HB100
Cover
Fig.28
Electrode Belt
Packing
Transmitter Body
#169-9820 #169-9835 #169-6567 #169-6562 #169-9730
#169-9810 #169-9800 #169-9840 #169-6280 #166-5120 #166-5150