Conversion to Natural Gas or LPG

19

Conversion to Natural Gas or LPG

Replacing the Burner Injectors

If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by contacting the After-Sales Service.

Choose the injectors to be replaced according to the table below.

The injector diameter, expressed in hundredths of a millimetre, is marked on the injector body.

To replace the injectors proceed as follows:

Remove the pan supports, the burner caps and flame speaders.

Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind of gas for which it is to be used.

The burners are made in such a way so as not to require regulation of the primary air.

Auxiliary,

 

Semi-Rapid

 

J

and Rapid

 

burners

 

Triple Ring burner

J

Fig. 19

Fig. 20

Table for the Choice of the Injectors

 

Cat: II 2H 3+

 

 

 

 

 

Burners

Nominal

Reduced

G30 - 28-30 mbar

G20 - 20 mbar

 

Power

Power

G31 - 37 mbar

 

 

kW

kW

 

 

 

Ø Injector

Ø Injector

 

 

 

 

 

 

1/100 mm

1/100 mm

Auxiliary (A)

1,00

0,30

50

72 (X)

 

 

 

 

 

Semi-Rapid (SR)

1,75

0,45

65

97 (Z)

 

 

 

 

 

Rapid (R)

3,00

0,75

85

115 (Y)

 

 

 

 

 

Triple Ring (TR)

3,50

1,50

95

135 (T)

 

 

 

 

 

Page 19
Image 19
CDA HCG 741 manual Conversion to Natural Gas or LPG, Replacing the Burner Injectors, Table for the Choice of the Injectors