CDA HCG 730, HCG 740 Adjusting The Gas Burner Minimum, Lubricating The Gas Tap

Models: HCG 730 HCG 740

1 32
Download 32 pages 50.65 Kb
Page 27
Image 27
ADJUSTING THE GAS BURNER MINIMUM

ADJUSTING THE GAS BURNER MINIMUM

For taps with adjusting screw inside the shaft (fig. 21):

using a screwdriver max. diameter 3 mm turn the screw inside the tap shaft until the flame setting is correct.

For taps with adjusting screw on the body (fig. 22):

using a screwdriver turn screw "A" until the flame setting is correct.

In some models with a gas-lighter incorporated into the knob, turn screw “A” via the hole in the microswitch.

Normally for LPG, fully tighten the adjustment screw.

LUBRICATING THE GAS TAP

If a gas tap is difficult to turn, disassemble it, clean it carefully with petrol and spread a little high-temperature-resistant grease on it.

These operations must be performed by a specialised engineer.

Figure 21

Figure 22

A

27

Page 27
Image 27
CDA HCG 730, HCG 740 installation instructions Adjusting The Gas Burner Minimum, Lubricating The Gas Tap