BURNERS AND GRIDS

These parts can be removed and cleaned with appropriate products.

After cleaning, the burners and their flame spreaders must be well dried and correct- ly replaced.

It is very important to check that the burner flame spreader and the cap have been correctly positioned. Failure to do so can cause serious problems.

In appliances with electric ignition, check that the electrode “S” (fig. 7) is always clean to ensure trouble-free sparking.

In the models with safety device, check that the probe “T” (fig. 7) next to each burn- er is always clean to ensure correct operation of the safety valves.

Both the probe and ignition plug must be very carefully cleaned.

Note: To avoid damage to the electric ignition do not use it when the burners are not in place.

GAS TAPS

Regular lubrication of the gas taps must only be performed by specialised engineers.

If the gas taps are not working properly call the After-Sales Service.

CONTROL KNOBS

The control knobs may be removed for cleaning but care should be taken not to damage the seal.