Table for the choice of the injectors

GB

 

 

 

 

Cat: II 2H3+

 

Nominal

Reduced

G 30 - 28-30 mbar

G 20

 

 

G 31 - 37 mbar

20 mbar

 

BURNERS

Power

Power

 

Tube ring

 

Tube ring

 

 

Ø injector

Ø injector

 

[kW]

[kW]

 

opening

opening

 

 

 

[1/100 mm]

[mm]

[1/100 mm]

[mm]

 

 

 

 

 

Auxiliary (A)

1,00

0,30

50

-

72 (X)

-

Semi-rapid (SR)

1,75

0,45

65

-

97 (Z)

-

Rapid (R)

3,00

0,75

85

-

115 (Y)

-

Triple-ring

3,50

1,50

95

-

135 (T)

-

Oven (left)

3,70

0,75

92

fully open

140

5

Grill (left)

2,50

-

80

fully open

120

4

Oven (right)

2,20

0,63

72

fully open

110

4

Grill (right)

2,00

-

70

fully open

105

2

 

INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)

 

 

 

BURNERS

 

Air necessary for combustion [m3/h]

Auxiliary (A)

 

2,00

 

 

 

Semi-rapid (SR)

 

3,50

 

 

 

Rapid (R)

 

6,00

 

 

 

Triple-ring

 

7,00

 

 

 

Oven (left)

 

7,40

 

 

 

Grill (left)

 

5,00

 

 

 

Oven (right)

 

4,40

 

 

 

Grill (right)

 

4,00

 

 

 

39