Table for the choice of the injectors
GB |
|
|
|
| Cat: II 2H3+ | |
| Nominal | Reduced | G 30 - | G 20 |
| |
| G 31 - 37 mbar | 20 mbar |
| |||
BURNERS | Power | Power |
| Tube ring |
| Tube ring |
|
| Ø injector | Ø injector | |||
| [kW] | [kW] | ||||
| opening | opening | ||||
|
|
| [1/100 mm] | [mm] | [1/100 mm] | [mm] |
|
|
|
|
| ||
Auxiliary (A) | 1,00 | 0,30 | 50 | - | 72 (X) | - |
1,75 | 0,45 | 65 | - | 97 (Z) | - | |
Rapid (R) | 3,00 | 0,75 | 85 | - | 115 (Y) | - |
3,50 | 1,50 | 95 | - | 135 (T) | - | |
Oven (left) | 3,70 | 0,75 | 92 | fully open | 140 | 5 |
Grill (left) | 2,50 | - | 80 | fully open | 120 | 4 |
Oven (right) | 2,20 | 0,63 | 72 | fully open | 110 | 4 |
Grill (right) | 2,00 | - | 70 | fully open | 105 | 2 |
| INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW) | |
|
|
|
BURNERS |
| Air necessary for combustion [m3/h] |
Auxiliary (A) |
| 2,00 |
|
|
|
| 3,50 | |
|
|
|
Rapid (R) |
| 6,00 |
|
|
|
| 7,00 | |
|
|
|
Oven (left) |
| 7,40 |
|
|
|
Grill (left) |
| 5,00 |
|
|
|
Oven (right) |
| 4,40 |
|
|
|
Grill (right) |
| 4,00 |
|
|
|