Electrical feeder cable connection

The operations must be executed by a qualified technician.

To connect the supply cable:

-Remove the screws securing the cover “A” on the rear of the cooker (fig. 60).

-Feed the supply cable through the cable clamp “D”. The supply cable must be of a suitable size for the current requirements of the appliance; see the section “Feeder cable section”.

-Connect the wires to the terminal block “B” as shown in the diagram in figure 61; or connect the phase wires to the terminal block “B” and the earth wire to the terminal PE as shown in figure 60.

-Take up any slack in the cable and secure with the cable clamp “D”.

-Replace the cover “A”.

Before effecting any intervention on the electrical parts of the appliance, the connection to the network must be interrupted.

Feeder cable section type H05RRF

230 V 3 x 0,75 mm2

Earth cable must be 2 cm longer than neutral and live cables.

PE

230 V

N

B

L D

L1 N PE (L2)

Fig. 61

A

Fig. 60

47

Page 47
Image 47
CDA RC9321 manual Electrical feeder cable connection, Feeder cable section type H05RRF