Cecilware BC301-IT, BC2-IT, BC302-IT specifications

Models: BC302-IT BC301-IT BC2-IT

1 21
Download 21 pages 55.82 Kb
Page 10
Image 10
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer.

TEMPERATURE SENSOR CALIBRATION

TEMP SENSOR CAL

ARE YOU SURE ?

Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer.

Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed

TEMP SENSOR CAL

temperature to match the reference thermometer. Depress one of the

### °F

[Hidden] Keys when the calibration is complete.

 

LOCKOUT TEMPERATURE

LOCKOUT TEMP

 

### °F

Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a Brew Cycle to begin unless the water is above the Lockout Temperature.

SLEEP TIMER

SLEEP TIMER

ON/OFF

Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockout Temperature if the machine has not started a Brew Cycle within two hours.

WARMER POWER

WARMER POWER

### %

Description – The Warmer Power feature allows the user to reduce the actual heating power of the warmers. The percentage displayed is percentage of maximum power.

WARMER TIMER

WARMER TIMER

ON/OFF

Description The Warmer Timer feature allows the user to set the maximum length of time a brew remains fresh while being warmed. Once the Warmer Timer has expired an alarm is generated. An alarm consists of a blinking warmer LED and (optionally) the audible alarm (buzzer) sounding. The Warmer Timer is reset (restarted) by cycling the warmer Off and On.

AUDIBLE ALARM

AUDIBLE ALARM

ON/OFF

Description – The Audible Alarm feature allows the user to enable/disable the buzzer from indicating that the Warmer Timer has expired.

WARMER TIME

WARMER TIME

### MINUTES

Description – The Warmer Time is the length of time that a warmer can be continuously energized before an alarm is generated.

WARMER REDUCTION

WARMER REDUCTION ON/OFF

Description – The Warmer Reduction feature allows the user to gradually reduce the actual heating power of the warmers. This reduction of power is taken over the Warmer Timer period.

REDUCTION PERCENTAGE

REDUCTION PCT

### %

Description – The Reduction Percentage is the percentage of Warmer Power that is gradually reduced over the Warmer Time.

WEEKDAY TIMER

WEEKDAY TIMER

ON/OFF

Description – The Weekday Timer function allows the system to automatically turn ON at a specified time and turn OFF at a specified time every weekday (Monday – Friday).

WEEKDAY TIME ON

WEEKDAY TIME ON

##:## #M

Description – The Weekday Time ON function allows the user to set the required weekday turn ON time.

10

Page 10
Image 10
Cecilware BC301-IT, BC2-IT, BC302-IT specifications