ERROR MODE

ERROR MODE

Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” using the Power Key located on the membrane keypad to reset any reported error

KEYPAD

! SYSTEM ERROR !

KEYPAD

Description – This screen is displayed and the unit is disabled when a key-press is detected during the initial application of power to the system. This test is not performed during a Power Key initiated “power-on” sequence.

Possible Causes – Membrane Keypad or someone depressing a key while applying power to the system

110/220VAC ON

! SYSTEM ERROR !

110/220VAC ON

Description – This screen is displayed and the unit is disabled when line voltage is detected before the Safety Relay is energized.

Possible Causes – Wiring or Safety Relay

110/220VAC OFF

! SYSTEM ERROR ! 110/220VAC OFF

Description – This screen is displayed and the unit is disabled when line voltage is not detected after the Safety Relay is energized.

Possible Causes – Wiring, Fuse, High Temp Limit Switch, Control Card, or Safety Relay

HIGH WATER TEMP

! SYSTEM ERROR ! HIGH WATER TEMP

Description – This screen is displayed and the unit is disabled when the present water temperature is sensed as being higher than 208 °F.

Possible Causes – Wiring, Power Triac, Control Card, or Water Temperature Sensor

OVER FLOW

! SYSTEM ERROR !

OVER FLOW

Description – This screen is displayed and the unit is disabled when the Over Flow Level Sensor is detecting the presence of water.

Possible Causes – Wiring, Fill Solenoid, Control Card or Level Sensor

NO FILL RESPONSE

! SYSTEM ERROR ! NO FILL RESPONSE

Description – This screen is displayed and the unit is disabled when the Fill Solenoid has been continuously energized (open & filling) for more than 15 minutes during the first fill or more than 30 seconds thereafter.

Possible Causes – Water Supply is turned off, Wiring, Control Card, Fill Solenoid, or Level Sensor

NO TEMP RESPONSE

! SYSTEM ERROR ! NO TEMP RESPONSE

Description – This screen is displayed and the unit is disabled when the Water Heater has been continuously energized (heating) for more than 45 minutes.

Possible Causes – Wiring, Control Card, Water Temperature Sensor, Power Triac, or Water Heater

DUMP #1 CLOSED

! SYSTEM ERROR ! DUMP #1 CLOSED

Description – This screen is displayed and the unit is disabled when the system has been brewing (dispensing) for more than one minute and the Level Sensor has not sensed the absence of water. Possible Causes – Wiring, Control Card, or Dump Solenoid.

TEMP SENSOR

! SYSTEM ERROR !

TEMP SENSOR

Description – This screen is displayed and the system is shut down when the Water Temperature Sensor is detecting an invalid (below 32°F or above 220°F) water temperature.

Possible Causes – Wiring, Control Card, or Temperature Sensor. 12