Installation Step 7

Install the Door Control and

Connect all Wiring

Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware.

The door control is typically attached directly to the wall. If installing into drywall, drill 5/32" holes and use the anchors provided. For pre-wired installations (as in new home construction), the multi-function door control can be mounted to a standard single gang box.

1.Strip 1/4" of insulation from one end of the bell wire and connect it to the two screw terminals on the back of the door control by color: white to 2 and white/red to 1. (Fig. 1)

2.Lighted door control: Fasten to wall with 6ABx1-1/2" self- tapping screws.

Multi-function:Remove the white cover by gently pushing both thumbs against upper corners of cover on the back side of the door control (Fig. 2). Fasten with 6ABx1-1/4" self- tapping screws (standard installation) or 6-32x1" machine screws (pre-wired installation) as follows: (Fig. 3)

Install bottom screw, allowing 1/8" to protrude from the wall.

Position bottom of door control over screw head and adjust for snug fit.

Install top screw with care to avoid cracking plastic housing. Do not overtighten.

Replace cover by inserting bottom tabs and snapping into place. To remove cover after mounting, gently pry at top with paper clip or small flat head screwdriver.

NOTE: After installation, a green indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).

3.Standard installation only: Run bell wire up wall and across ceiling to opener. Use insulated staples to secure wire in several places. Be careful not to pierce the wire with a staple, creating a short. If your access door is near the garage door, you may run this wire with the Safety Reversing Sensor wires along the top of the rail. See page 14.

4.Remove Control Center door on right panel of opener to access the terminal screws.

WARNING

DO NOT CONNECT TO LIVE ELECTRICAL WIRING. CONNECT ONLY TO 24 VOLT LOW VOLTAGE WIRES. CONNECTION TO LIVE WIRES OR HIGHER VOLTAGE MAY CAUSE SERIOUS INJURY FROM SHOCK, BURN OR ELECTROCUTION.

Children operating or playing with a garage door opener can

injure themselves or others. The garage door could close and cause serious injury or death. Do not allow children to operate the push button or the remote control transmitter.

A moving garage door could injure someone under it. Activate

the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.

Do NOT connect the power and operate the opener at this time. See Step 9 on page 18.

Outside Keylock connections (see Accessories)

To opener terminal screws: white to 2; white/red to 1

Figure 1

 

 

Figure 2

 

Terminal

 

 

 

 

Screws

 

 

 

 

WHT

 

 

 

 

2

RED WHT

RED WHT

 

RED

1

2

1

2

1

 

 

 

 

Lighted

Multi-Function

REMOVE COVER

Door Control

Door Control

 

 

STANDARD

INSTALLATION

PRE-WIRED INSTALLATION

LOCK

LIGHT

To Replace,

Insert Bottom Tabs First

Figure 3

LOCK

24 Volt

LIGHT

To Replace,

2-Conductor

Insert Bottom Tabs First

Bell Wire

5.Thread all wires through the opening at the base of the drive shaft cover (Fig. 4).

6.Insert the remaining wire through the hole in the power unit and strip 1/4" of insulation from each set of wires.

7.Connect door control wire to the opener terminal screws: white to 2 and white/red to 1.

8.Connect sensor wires to the opener terminal screws: white to 2 and white/black to 3.

9.Attach the User Safety Instruction label to the wall near the door control, and the Maintenance Instruction label in a prominent location on the inside of the garage door.

Page 28 explains how to operate the opener using the door control.

Hardware Shown Actual Size

 

 

 

 

 

 

 

 

6ABx1-1/2" Screw

 

 

 

 

 

 

 

 

 

 

Insulated

 

 

 

 

 

 

Lighted Door Control Button

 

 

 

 

 

 

 

 

 

 

 

Staples

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6AB x 1-1/4" Screw

 

6-32 x 1" Screw

Multi-function (std installation)

Multi-function (pre-wired)

Anchors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To

 

 

 

Sensors

 

 

 

To

 

 

Figure 4

Door

 

 

Control

 

 

WIRING TO

 

 

 

CONTROL CENTER

 

 

 

1. INSERT WIRES

 

 

 

THROUGH

 

 

 

OPENING IN

 

 

Terminal

DRIVE SHAFT

 

 

Screws

COVER

 

 

3

2. PUSH WIRING

 

 

2

1

 

 

THROUGH HOLE IN

 

 

 

Control

 

 

CHASSIS

 

 

(ABOVE CONTROL

Center

 

 

 

 

CENTER) AND

 

 

 

 

 

 

CONNECT TO

Door Control

 

Sensor

OPENER TERMINAL

Connections

 

Connections

SCREWS

(dotted line)

 

 

 

1

2

3

 

OPENER TERMINAL SCREWS