HAVING A PROBLEM?
1. My door will not close and the light bulbs blink

on my motor unit: The safety reversing sensor

must be connected and aligned correctly before the

garage door opener will move in the down direction.

• Verify the safety sensors are properly installed,

aligned and free of any obstructions. Refer to

Installation Step 10: Install The Protector

Bell Wire

System®.

• Check diagnostic LED for flashes on the motor

unit then refer to the Diagnostic Chart on the

following page.

2. My remotes will not activate the door:

• Reprogram remotes following the programming

instructions. Refer to Programming.

• If remote will still not activate your door, check

diagnostic LED for flashes on motor unit then

refer to Diagnostic Chart on the following page.

3. My door reverses for no apparent reason:

Repeat safety reverse test after adjustments to

force or travel limits. The need for occasional

adjustment for the force and limit settings is normal.

Safety Sensor

Sending Eye Safety Sensor (Amber Indicator Light)

1

2

3

1

"Learn" Button LED or

Diagnostic

LED

Receiving Eye Safety Sensor (Green Indicator Light)

Weather conditions in particular can affect door

travel.

• Manually check door for balance or any binding

problems.

• Refer to Adjustment Step 2, Adjust the Force.

4. My door reverses for no apparent reason after
fully closing and touching the floor: Repeat

safety reverse test after adjustments to force or

travel limits. The need for occasional adjustment for

the force and limit settings is normal. Weather

conditions in particular can affect door travel.

• Refer to Adjustment Step 1, Adjust the UP and

DOWN Travel Limits. Decrease down travel by

turning down limit adjustment screw clockwise.

5. My lights will not turn off when door is open:

• The garage door opener is equipped with a

security light feature. This feature activates the

light on when the safety sensor beam has been

obstructed.

6.My motor unit hums briefly:

First verify that the trolley is against the stop bolt.

Release the door from the opener by pulling the Emergency Release Rope.

Manually bring the door to a closed position.

Loosen the chain by adjusting the outer nut 4 to 5 turns. This relieves the tension.

Run the motor unit from the remote control or door control. The trolley should travel towards the door and stop. If the trolley re-engages with the door, pull the Emergency Release Rope to disengage.

Decrease the UP travel by turning the UP Travel adjustment screw 2 full turns away from

the arrow.

Re-tighten the outer nut so the chain is a

1/4" (6 mm) above the base of the rail. (When the door is reconnected and closed, the chain will sag. This is normal.)

If the trolley does not move away from the bolt, repeat the steps above.

33