PROGRAMMING THE RADIO RECEIVER

SET SECURITY MODE

P R O G R A M M I N G

WARNING

The Universal Receiver can be used with up to 15 rolling code transmitters or passwords in HIGH security mode. Alternately, it can be used with up to 31 of any type transmitter in NORMAL security mode, including any combination of rolling code, billion code, or dip switch remotes.

The jumper must be set at the HIGH position for the receiver to operate in HIGH security mode. It must be set at NORMAL position to operate at the NORMAL mode (Figure 1).

When changing from NORMAL to HIGH security mode, any previous transmitter codes must be erased. Repeat Steps 2 and 3 in the Programming Section below to reprogram the receiver for each remote control transmitter in use.

To prevent possible SERIOUS INJURY or DEATH from electrocution:

• Be sure power is not connected BEFORE installing the receiver.

To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:

ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters.

Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.

The receiver is factory set at HIGH.

SET OUTPUT DURATION

WARNING

To prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED.

For commercial applications, the receiver can be set for either constant or momentary closure on the output contacts. Use of constant closure is prohibited on residential garage door openers because it overrides the safety reversal devices.

With the jumper in the "M" (Momentary) position, the contacts will close for 1/4 second regardless of the length of radio transmission. With the jumper in "C" (Constant) position, the contacts will stay closed as long as the radio continues transmitting (Figure 2).

The receiver is factory set at M.

PROGRAMMING THE REMOTE TO THE RECEIVER

1.Pry open the front panel of receiver case with a coin or a screwdriver. Re-connect power to operator (Figure 3).

2.Press and release the "learn" button on the receiver. The learn indicator light will glow steadily for 30 seconds.

3.Within 30 seconds, press and hold the button on the hand-held remote that you wish to operate your gate operator.

FIGURE 1

Security Mode

Jumper

Terminals

 

HIGH

SECURITY MODE

FIGURE 2

CONSTANT Jumper

OPERATION

Output

Duration

Terminals

M

Security Mode

Jumper

Terminals

 

NORMAL

SECURITY MODE

MOMENTARY Jumper

OPERATION

Output

Duration

Terminals

M

The opener will now operate when the push button on either the receiver or the remote control is pressed.

FIGURE 3

OPENING RECEIVER

Repeat Steps 2 and 3 for each remote control that will be used to operate the gate operator.

TO ERASE ALL REMOTE CONTROL CODES

Press and hold the “learn” button on the receiver panel until the indicator light turns off (about 6 seconds). All remote codes are now erased. Then follow the steps above to reprogram each remote control.

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Connect

OPEN RECEIVER

 

Antenna

 

24V 12V

Indicator Light

Learn Button

 

P2

Output Duration

 

C

 

 

M

Terminals

 

 

HIGH

NORM

Security Mode

Power Supply

 

 

 

 

Jumper

19