O P E R AT I O N A N D M A I N T E N A N C E

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of SEVERE INJURY or DEATH:

1.READ AND FOLLOW ALL INSTRUCTIONS.

2.NEVER let children operate or play with gate controls. Keep the remote control away from children.

3.ALWAYS keep people and objects away from the gate.

NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4.Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of INJURY or DEATH.

DESCRIPTION

TASK

Hall Effect (RPM) Sensor

Check for wear, oil damage and

 

proper operation

External Entrapment

Check for proper operation

Protection Systems

 

Gate Caution Signs

Make sure they are present

Manual Disconnect

Check and operate bypass valve

Drive Rail

Check for damage and wear

Gate

Inspect for wear or damage

Accessories

Check all for proper operation

Electrical

Inspect all wire connections

Frame Bolts

Check for tightness

Fluid Level

Keep at least 3/4 Full

Fittings

Check for leaks

Total Unit

Inspect for wear or damage

NOTES:

1.Severe or high cycle usage will require more frequent maintenance checks.

2.Inspection and service should always be performed anytime a malfunction is observed or suspected.

3.Limit switches may have to be reset after any major drive chain adjustments.

4If lubricating chain, use only a proper chain lube spray or a lightweight motor oil. Never use grease or silicone spray.

5.Use the emergency release ONLY when the gate is not moving.

6.KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person make repairs to gate hardware.

7.The entrance is for vehicles ONLY. Pedestrians MUST use separate entrance.

8.Disconnect ALL power BEFORE performing ANY maintenance.

9.ALL maintenance MUST be performed by a LiftMaster professional.

10.SAVE THESE INSTRUCTIONS.

 

CHECK AT LEAST ONCE EVERY

3 MONTHS

6 MONTHS12 MONTHS

X

 

 

 

 

X

 

OUT

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

X

CHECK

 

 

 

 

 

 

 

X

 

 

 

X

X

COMPLETE

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

X

X

5.When servicing, please do some “house cleaning” of the operator and the area around the operator. Pick up any debris in the area. Clean the operator as needed.

6.It is suggested that while at the site voltage readings be taken at the operator. Using a Digital Voltmeter, verify that the incoming voltage to the operator it is within ten percent of the operators rating.

23