O P T I O N A L C O N T R O L D E V I C E S
ACCESSORY WIRING
STOP/RESET AUXILIARY CONTROL WIRING
Terminals 6 & 5 (Com) - Open
These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads,
Terminals 7 & 5 (Com) - Open Override Control Input
These terminals are intended for use only with the open control of a
Terminals 4 & 5 (Com) - Close Override Control Input
These terminals are intended for use only with the close control of a
Terminals 8 & 5 (Com) - Interrupt (Safety) Loop Input
These terminals are intended for use with a loop detector. This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close.
Terminals 2 & 5 (Com) - Shadow Loop Input
These terminals are intended for use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active.
The GL operator controller board senses commands using +24VDC from terminal #3. Commands are seen when +24VDC are applied to the controller’s input terminals. NOTE: The GL controller has built in surge suppression circuitry however please take precautions when adding any additional surge protection.
Terminals 1 & 5 (Com) - Single Button Input
These terminals are intended for use with a radio receiver in a residential application or as a single button control. This allows the user to open the gate by activating the transmitter when the gate is closed or between limits. This input also gives the user the ability to close the gate by activating the transmitter when the gate is on the open limit.
Terminals 3 & 5 (Com) - Stop/Reset Control Input
These terminals are intended for use with a single stop/reset button or the stop control of a
12 3 4 5 6 7 8 9 10 11 12 13 14
1 | 2 | 3 |
| 5 | 6 |
7 | 8 | 9 |
| ||
| 0 | # |
Radio (Signal Button) Input
Open Override |
| |
Control Input | 3 4 5 6 7 8 9 | |
|
| |
N.O. | Com 3 4 5 7 8 8 |
Close Override
Control Input
1 2 3 4 5 6 7
1 2 3 4 5 6
N.O. Com
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6
Shadow Loop
Input
Interrupt (Safety)
Loop Input
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6
Single Button
Input
Stop/Reset Control
Input
21