O P T I O N A L C O N T R O L D E V I C E S

ACCESSORY WIRING

STOP/RESET AUXILIARY CONTROL WIRING

Terminals 6 & 5 (Com) - Open

These terminals are intended for use as a general open control. Accessories that may be wired to this input include: Telephone Entry Systems, Radio Receiver (Commercial Applications), Exit Loop Detector, Keypads, 7-Day Timer. NOTE: Will not override a double entrapment (signalled by the gate stopped and entrapment alarm on).

Terminals 7 & 5 (Com) - Open Override Control Input

These terminals are intended for use only with the open control of a three-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to open. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye.

Terminals 4 & 5 (Com) - Close Override Control Input

These terminals are intended for use only with the close control of a three-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to close. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device. This will allow the user, in emergencies, to override a failed accessory such as a loop detector or photo-eye.

Terminals 8 & 5 (Com) - Interrupt (Safety) Loop Input

These terminals are intended for use with a loop detector. This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close.

Terminals 2 & 5 (Com) - Shadow Loop Input

These terminals are intended for use with a loop detector and is primarily used on swing gate operators. This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active.

The GL operator controller board senses commands using +24VDC from terminal #3. Commands are seen when +24VDC are applied to the controller’s input terminals. NOTE: The GL controller has built in surge suppression circuitry however please take precautions when adding any additional surge protection.

Terminals 1 & 5 (Com) - Single Button Input

These terminals are intended for use with a radio receiver in a residential application or as a single button control. This allows the user to open the gate by activating the transmitter when the gate is closed or between limits. This input also gives the user the ability to close the gate by activating the transmitter when the gate is on the open limit.

Terminals 3 & 5 (Com) - Stop/Reset Control Input

These terminals are intended for use with a single stop/reset button or the stop control of a three-button station that is installed within line of site of the gate. This input functions to stop the gate or to reset the gate after an entrapment fault. Note: This input uses a normally closed circuit and the operator will not run until a stop control is installed. NOTE: It is strongly recommended that a jumper be used for testing purpose only and not for normal operation.

12 3 4 5 6 7 8 9 10 11 12 13 14

1

2

3

 

5

6

7

8

9

 

 

0

#

Radio (Signal Button) Input

Open Override

 

Control Input

3 4 5 6 7 8 9

 

 

N.O.

Com 3 4 5 7 8 8

Close Override

Control Input

1 2 3 4 5 6 7

1 2 3 4 5 6

N.O. Com

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6

Shadow Loop

Input

Interrupt (Safety)

Loop Input

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6

Single Button

Input

Stop/Reset Control

Input