RS-232 Control Code:
For installations requiring more sophistication the A4603 supports
Baud Rate: 19200, 8N1 (8Bit Data, No Parity, 1 Stop Bit) Each transmission = 8 ASCII bytes
Check Sum = The sum of the first 7 bytes inverted and truncated
Note: the check sum for each command is included in the following charts.
There are two possible responses generated when a command is received: ack - This acknowledges that the command was received and it had a valid
check sum.
ZZZ- This means that the command was not understood or could not be decoded correctly. It could also mean that the check sum was not valid.
Serial Cable Pin Out |
|
A4603 | PC |
Zone 1 Commands
Function | ASCII Command | Hex Command | |
Zone 1 Power Toggle | A46Z1PL- | 41 34 36 5A | 31 50 4C 2D |
|
|
| |
All Power Toggle | A46Z1PA8 | 41 34 36 5A 31 50 41 38 | |
|
|
|
|
Zone 1, Select Source 1 | A46Z1S1E | 41 34 36 5A | 31 53 31 45 |
Zone 1, Select Source 2 | A46Z1S2D | 41 34 36 5A | 31 53 32 44 |
Zone 1, Select Source 3 | A46Z1S3C | 41 34 36 5A | 31 53 33 43 |
|
|
| |
Zone 1, Select Source 4 | A46Z1S4B | 41 34 36 5A 31 53 34 42. | |
|
|
| |
Zone 1, Volume Up | A46Z1V+H | 41 34 36 5A 31 56 2B 48 | |
|
|
| |
Zone 1, Volume Down | 41 34 36 5A 31 56 2D 46 | ||
|
|
| |
Zone 1, Volume Reset | A46Z1VC0 | 41 34 36 5A 31 56 43 30 | |
|
|
| |
Zone 1, Mute | A46Z1MT+ | 41 34 36 5A 31 4D 54 28 |
Zone 1, Request Status
A46Z1SF0
41 34 36 5A 31 53 46 30
Zone 1, Status Clear
A46Z1SC3
41 34 36 5A 31 53 43 33