Chauvet 1200E user manual Error Messages, Technical Information

Models: 1200E

1 30
Download 30 pages 28.2 Kb
Page 26
Image 26
Error Messages

Technical Information

Error Messages

Message

Cause(s)

Action(s)

 

 

 

 

Lamp Startup Fail

The lamp has not started after being

Check lamp

 

struck.

Check lamp socket and wiring

 

 

Check ballast and igniter

 

 

 

 

Temperature Sense Fail

There is no communication with

Check sensor wiring

 

temperature sensor.

Check sensor integrity

 

 

Check control board

Lamp Hot Protection

Fixture temperature is higher than 105º C;

Check fans

 

lamp was switched to low power for safety.

Check fan wiring

 

 

Clean vents

 

 

 

 

Lamp Hot Power Off

Fixture temperature is 110º C or higher;

Check fans

 

lamp was switched to off for safety.

Check fan wiring

 

 

Clean vents

Maintenance Fixture

Fixture Maintenance timer expired.

Proceed with maintenance and reset timer

Lamp On Over 700 Hour

Lamp change is overdue.

Change lamp

 

 

 

 

Memory Initial Fail

Memory chip error found.

Change main board

 

 

 

 

Fan 1 Error

The indicated fan is not working.

Check fan

Fan 2 Error

 

Check fan wiring

Fan 3 Error

 

 

 

Fan 4 Error

 

 

 

Fan 5 Error

 

 

 

Fan 6 Error

 

 

 

CPU-B Error

There is no communication with the

Check sensors wiring and position

CPU-C Error

indicated auxiliary CPU.

Check stepper motor, belt, and driver board

CPU-D Error

 

Check control boards

CPU-E Error

 

 

 

CPU F Error

 

 

 

CPU G Error

 

 

 

 

 

 

 

Pan Home Sensor Error

The moving head failed going to home

Check moving head’s free movement

Pan Encode Error

position after power up or fixture reset.

Check sensors’ wiring and position

Tilt Home Sensor Error

 

Check stepper motor, belt ,and driver board

Tilt Encode Error

 

Check the corresponding control board

 

 

Check main control board

 

 

 

 

Shutter Reset Fail

The indicated moving part failed going to

Check part’s free movement and integrity

Dimmer Reset Fail

home position after power up or fixture

Check sensors’ wiring and position

Color 1 Reset Fail

reset.

Check stepper motor, belt, and driver board

Color 2 Reset

 

Check the corresponding control board

Cyan Reset Fail

 

Check main control board

Magenta Reset Fail

 

 

 

Yellow Reset Fail

 

 

 

3200 K Filter Reset Error

 

 

 

Frost Reset Fail

 

 

 

Zoom Reset Fail

 

 

 

 

 

 

 

-22-