Chauvet color ado1ip Troubleshooting Guide, Technical Information, Symptom, Causes, Actions

Models: color ado1ip

1 28
Download 28 pages 33.51 Kb
Page 23
Image 23
Troubleshooting Guide

 

 

 

 

 

 

 

Technical Information

 

 

 

 

 

 

 

Troubleshooting Guide

 

 

 

 

 

Symptom

 

Cause(s)

 

Action(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

General low light intensity

 

Dirty lens assembly

 

Clean the fixture regularly

 

 

Misaligned lens assembly

 

Install lens assembly properly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A single LED (Red,

 

Faulty LED

 

Replace the LED board

 

Green, Blue or White)

 

Faulty LED board

 

Replace the LED board

 

 

does not illuminate

 

 

 

A group of LEDs (Red,

 

Faulty LED

 

Replace the LED board

 

 

 

Faulty LED board

 

 

Replace the LED board

 

Green, Blue or White)

 

 

 

does not illuminate

 

Faulty LED driver

 

• Replace the LED driver board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None of the LEDs are

 

Faulty LED PCB

 

Replace the LED board

 

 

Faulty LED Driver PCB

 

• Replace the LED driver board

 

illuminating

 

 

 

 

Faulty main PCB

 

• Replace the Display / Main board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Breaker/Fuse keeps

 

Excessive circuit load

 

Check total load placed on the electrical circuit

 

blowing

 

Short circuit along the power wires

 

• Check for a short in the electrical wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No power

 

• Check for power on power outlet

 

Fixture does not power up

 

Loose or damaged power cord

 

Check power cord

 

 

 

Blown internal fuse

 

Replace internal fuse

 

 

 

Faulty internal power supply

 

Replace internal power supply

 

 

 

 

 

 

 

 

 

 

 

Wrong DMX addressing

 

• Check Control Panel and unit addressing

 

 

 

Damaged DMX cables

 

Check DMX cables

 

Fixture does not respond

 

Wrong polarity on the controller

 

Check polarity switch settings on the controller

 

to DMX

 

Loose DMX cables

 

Check cable connections

 

 

 

 

 

 

 

Faulty DMX interface

 

Replace Main PCB

 

 

 

Faulty Main PCB

 

Replace Main PCB

 

 

 

 

 

 

 

 

 

 

 

 

Non DMX cables

 

Use only DMX compatible cables

 

 

 

Bouncing signals

 

Install terminator as suggested

 

 

 

• Long cable / low level signal

 

Install an optically coupled DMX splitter right

 

DMX signal problems

 

 

 

 

 

after fixture with strong signal

 

 

 

 

 

 

 

 

 

 

 

Too many fixtures

 

Install an optically coupled DMX splitter after

 

 

 

 

 

 

 

unit #32

 

 

 

Interference from AC wires

 

• Keep DMX cables separated from power cables

 

 

 

 

 

 

 

or black lights

 

 

 

 

 

 

 

 

 

If you still experience technical problems after trying the above solutions, contact CHAUVET® Technical Support.

COLORado™ 1 IP User Manual Rev. 01c