COLORDASH™ PARService Maintenance Guide
Symptom(s)
Possible Solution(s)
1 or more LED’s are not | Clean the fixture regularly to avoid any such failure. This fixture is convection | ||
cooled, which means that if the surface is kept clean and free of debris, then | |||
illuminating | |||
proper cooling will be allowed to occur |
| ||
|
| ||
| An LED may have failed, resulting in an open circuit. In this event, all of the | ||
| red, green, or blue in a single module will no longer illuminate. This does not | ||
| mean that all of the LEDs have failed, but the circuit is wired in series. | ||
| An LED may have failed, resulting in a short circuit. In this event, only the | ||
| single LED which has failed will no longer function. This does not mean that all | ||
| of the LEDs have failed, but the circuit is wired in series. | ||
| |||
| purchased directly from Chauvet | Part#: | |
1 or more LED’s are producing | Check that the lens assembly is installed properly. If the lens assembly is not | ||
aligned properly over the LEDs, then they will not project fully | |||
very low output | |||
| |||
| |||
| purchased directly from Chauvet | Part#: | |
Breaker/Fuse keeps blowing | Check total load placed on the electrical circuit | ||
| Check for a short in the electrical wiring: internal and/or external | ||
Device has no power | Check device’s fuse (internal) |
| |
| Check for power on Mains |
| |
| Check cable connections The COLORdash™ PAR cables must be firmly | ||
| connected for operation |
| |
| |||
| for repair; however, a replacement part can be ordered directly from Chauvet | ||
|
| Part#: | |
Fixture is not responding to DMX | Check Control Panel settings for correct addressing | ||
|
|
| |
| Check DMX cables |
| |
|
| ||
| Check polarity switch settings on the controller | ||
|
|
| |
| Check cable connections |
| |
|
|
| |
| Call service technician |
| |
|
| ||
| |||
| directly from Chauvet | Part#: | |
Loss of signal | Use only DMX cables |
| |
|
|
| |
| Install terminator |
| |
|
| ||
| Note: Keep DMX cables separated from power cables or black lights | ||
|
|
| |
|
| ||
not function, or does not function | Make sure connector is firmly connected to device | ||
properly |
|
| |
| The COLORdash™ PAR fixture must be in the correct mode in order to properly | ||
| respond to the | ||
| onboard Control Panel |
| |
Stand alone operation | This fixture has | ||
onboard Control Panel |
| ||
|
| ||
|
| ||
If you still have a problem after trying the above solutions, please contact CHAUVET | |||
Technical Support at the location on page 28. |
|
COLORdash™ Par User Manual | 29 | 9/4/2008 12:09 PM |