Chauvet 6000X dEMo, SoFt, Self Demonstration, dF.SE - Fixture Reset excludes Pan & Tilt

Models: 6000X LEG-6000

1 19
Download 19 pages 60.17 Kb
Page 13
Image 13
{dF.SE} - Fixture Reset (excludes Pan & Tilt)

Operating Instructions

{dF.SE} - Fixture Reset (excludes Pan & Tilt)

This function will re-initialize the fixture with exception of the Pan and Tilt motors.

FUNCTION

SET TO

NOTES

dF.SE

Off

Normal

On

Reset unit

{LP.ti} – Lamp Time

The (lamp time) readout displays the number of hours the lamp has been in use. It is not uncommon to find new fixtures with a few logged hours. This means the fixture was thoroughly tested prior to delivery.

1.Press the [MENU] button until the display reads “ΛΠ.τι”.

2.Press [SELECT] button to read the number of hours used.

3.Press both [▼▲ SELECT] buttons at the same time to reset the lamp counter to zero if changing a lamp.

{Fi.ti} – Fixture Timer

The (Fixture Timer) readout displays the total number of operating hours of the fixture. It is not uncommon to find new fixtures with a few logged hours.

Self Demonstration

{dEMo} – Self-demo

This function will execute the built-in program in the fixture.

FUNCTION

SET TO

NOTES

dEMo

Off

Normal

On

Run self-demonstration

{SoFt} – Demo speed

You can set the pace of the demo to either quick or fast.

FUNCTION

SET TO

NOTES

SoFt

Off

Quick paced

On

Slow paced