Chauvet LEG-6000 Dip Switches settings explained, Bit Movement, All Off, 1-On, 2-On, 3-On

Models: 6000X LEG-6000

1 19
Download 19 pages 60.17 Kb
Page 16
Image 16
8 Bit Movement

Appendix

CHANNEL

VALUE

FUNCTION

 

 

Beam Effect

 

000 Ù 063

Full Beam

8

064 Ù 127

Frost Filter

 

128 Ù 143 Flat and wide beam effect at 0°

 

144 Ù 255

Flat and wide beam effect 90° adjustment

9

 

Zoom

000 Ù 255

10° > 30°

 

10

 

Pan

000 Ù 255 0° > 570° ( 128 = center)

 

11

 

Tilt

000 Ù 255 0° > 270° (128 = center)

 

12

000 Ù 255

Pan (Fine)

13

000 Ù 255

Tilt (Fine)

 

 

Control

 

000 Ù 007 Utilizes an internal ramp to provide smooth Pan/Tilt

 

 

movement and adjustment

 

008 Ù 063 Disables the internal ramp to provide faster Pan/Tilt

 

 

movement and adjustment

 

064 Ù 127 Color calibration

14

 

Pan: Color Wheel

 

 

Tilt: Cyan

 

 

Pan (Fine): Magenta

 

 

Tilt (Fine): Yellow

 

 

( See Appendix, Color Calibration)

 

128 Ù 191 Save calibration settings after 3 seconds

 

192 Ù 255 Reset all motors after 3 seconds (does not reset calibration)

 

 

Lamp ON/OFF

 

000 Ù 047

Standby

15048 Ù 095 Hold 3 seconds for Lamp ON

096 Ù 159 Standby

160 Ù 207

Hold 3 seconds for Lamp OFF

208 Ù 255

Standby

8 Bit Movement

In the 8 bit Pan/Tilt resolution setting both (FINE) channels is removed. All other channel parameters remain the same as in the “DMX Channel Values” table.

CHANNEL

FUNCTION

 

CHANNEL

FUNCTION

 

CHANNEL

FUNCTION

 

 

 

 

 

 

 

 

1

Dimmer

6

Yellow

11

Tilt

 

 

 

 

 

 

 

 

2

Shutter/Strobe

7

Color Macro

12

Control

 

 

 

 

 

 

 

 

3

Color Wheel

8

Beam

13

Lamp ON/OFF

 

 

 

 

 

 

 

 

4

Cyan

9

Zoom

 

 

 

 

 

 

 

 

 

 

 

5

Magenta

10

Pan

 

 

 

 

 

 

 

 

 

 

 

Dip Switches (settings explained)

DIP SWITCH

EVENT

NOTES

 

The lamp will strike first. If striking of the lamp succeeds, in approximately

 

All Off

15 seconds the fixture’s motors will be powered and initialized. If the lamp

This is the default setting on the fixture and

does not strike, the remainder of the fixture will not initialize and you will

helps in reducing the amount of striking or

 

not have control of the fixture. Please wait 15 minutes before re-

inrush current used by the fixture upon startup.

 

starting the fixture, otherwise perform a service check.

 

1-On

Lamp and motors are powered at the same time.

Will consume the most amount of inrush current

in the startup phase.

 

 

2-On

Only the lamp will turn on in the fixture

 

1-On, 2-On

 

 

 

3-On

This switch will terminate the dmx connection.

Use only at the end of a DMX daisy chain.

LEG-6000 User Manual

16

Revision: 2007-03-06/09:06

Page 16
Image 16
Chauvet LEG-6000, 6000X user manual Dip Switches settings explained, Bit Movement, All Off, 1-On, 2-On, 3-On